Pro-flo efi installation instructions, Power on enter/exit, Up / down – Edelbrock 3530 User Manual
Page 30: Up down up down, Up down, Calibra tion module diagram exit exit

30
Pro-Flo EFI Installation Instructions
©2005 Edelbrock Corporation
Rev. 2/05
Brochure #63-0273
Catalog #3530 & #3531
FUEL @ ____ 2000:
±0%
EXIT = scroll ENTER
POWER ON
ENTER/EXIT
UP
DOWN
UP
DOWN
UP
DOWN
UP / DOWN
UP / DOWN
ENTER/EXIT
ENTER/EXIT
UP / DOWN
ENTER/EXIT
SAVE
RESTORE
EXIT
EXIT
UP / DOWN
WEBER/ EDELBROCK
Pro-Flo EFI System
(1-2 second commercial )
RPM: 3000 FUEL: 4.0 ms
VAC: 12.0Hg SPK: 36
˚
TH20: 180
˚
F TPS: 28
˚
TAIR: 98
˚
F Volt: 14.5
Idle: 25% RPM: 3000
TPS: 28
˚
Target:
950
RPM: 3000 –> •••••••••
VAC: 12.0 –> ••••
(software identification)
ECU: Q1.3 (c) WEBER ’93f
CAL: EDEL xxxx CM: 1.6
< FUEL MODIFIERS >
ENTER to select
< SPARK MODIFIERS >
ENTER to select
FUEL @ WOT 1000:
±0%
EXIT = scroll ENTER
FUEL @ 06" 1000:
± 0%
EXIT = scroll ENTER
FUEL @ 12" 1000:
± 0%
EXIT = scroll ENTER
FUEL @ 18" 1000:
± 0%
EXIT = scroll ENTER
Transient Fuel:
± 0%
EXIT = scroll ENTER
Cold Start Fuel:
± 0%
EXIT = scroll ENTER
Global Fuel Mod:
± 0%
EXIT = scroll ENTER
FUEL @ ____ 1000:
±0%
EXIT = scroll ENTER
FUEL @ ____ 3000:
± 0%
EXIT = scroll ENTER
FUEL @ ____ 4000:
± 0%
EXIT = scroll ENTER
FUEL @ ____ 5000:
± 0%
EXIT = scroll ENTER
FUEL @ ____ 7000:
± 0%
EXIT = scroll ENTER
SPRK @ WOT 1000:
±0
˚
EXIT = (+) = (
-
)
SPRK @ 9" 1000:
± 0
˚
EXIT = (+) = (
-
)
SPRK @ 18" 1000:
± 0
˚
EXIT = (+) =(
-
)
SPRK @ ____ 1000:
±0
˚
EXIT = scroll ENTER
SPRK @ ____ 1750:
±0
˚
EXIT = scroll ENTER
SPRK @ ____ 2500:
±0
˚
EXIT = scroll ENTER
SPRK @ ____ 3500:
± 0
˚
EXIT = scroll ENTER
SPRK @ ____ 4500:
± 0
˚
EXIT = scroll ENTER
SPRK @ ____ 6000:
± 0
˚
EXIT = scroll ENTER
Global SPRK Mod:
± 0
˚
EXIT = scroll ENTER
UP
DOWN
UP
DOWN
ENTER
EXIT
UP
DOWN
ENTER
EXIT
UP
DOWN
Target Idle RPM: 950
EXIT = scroll ENTER
Idle Fuel Mod:
± 0%
EXIT = (+) = ( - )
UP
DOWN
Idle Spark Mod:
± 0
˚
EXIT = scroll ENTER
Idle Spd Actvty:
± 0%
EXIT = (+) = ( - )
Rev limiter RPM: 6750
EXIT = scroll ENTER
Base Ti m’g set: OFF
EXIT = scroll ENTER
Closed loop fuel: OFF
EXIT = scroll ENTER
Idle Control: OFF
EXIT = scroll ENTER
SAVE data set: A/B/C
EXIT = scroll ENTER
RESTORE: baseA/B/C
EXIT = scroll ENTER
Saving In progress…
Saved to data set #A
Press EXIT
Restore In progress…
Data set #A RESTORED
Press EXIT
(Return to main menu)
< MISC. MODIFIERS>
ENTER to select
(FROM ANYWHERE IN MENU)
(NOTICE: Some values shown represent arbitrary examples)
(DIAGNOSTIC error messages will flash on any screen)
CALIBRA
TION MODULE DIAGRAM
EXIT
EXIT