14-SAFETY DEVICES AND ALARMS
Technical Dept. - All rights reserved - Reproduction is prohibited
WRITTEN ON THE
DISPLAY
TYPE OF PROBLEM
SOLUTION
A08
FLUE GAS FAN
Faulty smoke fan.
Check that the lower compartment is clean (see the pages
dedicated to stove cleaning) and verify that it is not obstructed;
clean it and cancel the alarm.
If the alarm persists, contact the service centre.
A09
SMOKE TEMPERA-
TURE PROBE
Smoke sensor fault.
Contact an authorised service centre to have the component
checked and, if needed, replace the component.
A11
GEAR REDUCER
Feed screw gear reducer fault.
The component is not working regularly.
Contact an authorised service centre to have the component
checked and, if needed, replace the component.
A13
BOARD TEMP
Electronic board overheating
Wait for the cooling phase to end, cancel the alarm and reduce
pellet loading (SETTINGS MENU - Pellet recipe). If the alarm
persists, contact the service centre. .
A14
ACTIVE SENSOR
Active sensor anomaly
Active Plus sensor operation anomaly. Contact an authorised
service centre to have the component checked and, if needed,
replace the component.
A18
WATER SIC
Water thermostat intervention
Water temperature is too high or thermostat operation anomaly.
If the alarm persists, contact the service centre.
A19
WATER PROBE
Fault with water sensor.
Possible fault in the safety component. Contact an authorised
service centre to have the component checked and, if needed,
replace the component.
A20
AUX PROBE
Auxiliary probe fault
Possible component fault.
Check that the probe inserted in the system respects the
characteristics specified in the instructions (see external probe).
Contact an authorised service centre to have the component
checked and, if needed, replace the component.
A21
Water pressure insufficient.
Verify hydraulic system pressure.