12-SETTINGS MENU

Technical Dept. - All rights reserved - Reproduction is prohibited

Puffer thermostat

To activate this option, connect a Normally Open (N.O.) contact thermostat to points 1 and 2 of the back 9-pole terminal board.

Even with this configuration the purpose of the room probe on the stove is only to control the heating system pump controlled by the

potential free contact on terminals 7-8-9.

POS.1-2 AUX INPUT : EXTERNAL THERMOSTAT/THERMOSTAT

BOILER/PUFFER/BOILER PROBE/PUFFER

POS.5-6 HOME AUTOMATION

POS.3-4 ROOM INPUT : ROOM PROBE

POS.7-8-9 AUX OUTPUT RELAY

The terminal block is at the back of the stove. Remove the two screws and protective cover to access it.

AUX INPUT