12-SETTINGS MENU

External probe

It makes it possible to work with system temperature adjustment. If installing an external probe on terminals 1 and 2 (NTC 10KOhm at

25°C b=3435) water temperature is automatically calculated by the electronics based on external temperature according to the curves

shown below:

The external probe must be installed on an external wall exposed towards North or North-West. If necessary, it is possible to correct the

value read by the probe by + 5 -5°C.

Boiler probe

To activate this option, connect a probe (NTC 10KOhm at 25°C b=3435) to points 1 and 2 of the back 9-pole terminal board.

The heat request occurs when the boiler probe reads a temperature that is 2°C below the one set by the accumulation temperature marked

by a tap in the temperature menu.

In this configuration, the aux output is configured as a potential free contact to control the 3-way valve (contact 7-8-9 of the back 9-pole

terminal board)

Boiler thermostat

To activate this option, connect a Normally Open (N.O.) contact thermostat to points 1 and 2 of the back 9-pole terminal board.

The heat request occurs when the boiler thermostat closes the contact.

Even with this configuration, the Aux output is configured as a potential free contact to control the 3-way valve (contact 7-8-9 of the back

9-pole terminal board).

Puffer probe

To activate this option, connect a probe (NTC 10KOhm at 25°C b=3435) to points 1 and 2 of the back 9-pole terminal board.

The heat request occurs when the boiler probe reads a temperature that is 2°C below the one set by the accumulation temperature marked

by a radiator in the temperature menu.

During installation with the puffer, stove operation is only and exclusively determined by the puffer probe and not by the room probe. The

purpose of the room probe on the stove is only to control the heating system pump controlled by the potential free contact N.O.: (max 5

ampere, not suitable for brushless pumps with upper start-up current) on terminals 8-9.