12-SETTINGS MENU

Technical Dept. - All rights reserved - Reproduction is prohibited

PWM PUMP

This function is used to set high efficiency pump speed.

To enter the function press:

from the Settings menu- press ok (E key), press the C-D key (arrow) and scroll up to PWM Pump, press OK (E key)- Modify the percentage

using the central C and D keys, press the E key to confirm.

FUNCT. ANTI-FREEZE

It consists in activating the pump (level 1) or the stove (level 2) and is automatically activated by the temperature read by the stove probe

and the temperature read by the external probe (if present and connected to the aux input).

The level 1 anti-freeze activation conditions (PUMP ON) are:

boiler temp < anti-freeze set +3°C

The level 2 anti-freeze activation conditions (PUMP and FLAME ON) are:

boiler temp = anti-freeze set

Anti-freeze activation conditions on external probe (if present) are:

ext_filtered temp < anti-freeze set -3°C

To enter the function, press and adjust anti-freeze set:

from the Settings menu- press ok (E key), press the C-D key (arrow) and scroll up to Antifreeze function and press OK (E key)- Activate and

set (from 1 to 5°C) or Deactivate the function and press the E key to confirm.

PELLET SENSOR

Optional Function.

B

E

INFO

OK

C

D

B

EXIT

SET THE SPEED OF THE

MODULATING HIGH EFFICIENCY

PUMP

SETTINGS-PUMP PWM

AUTO

B

E

INFO

OK

C

D

B

EXIT

SET THE ACTIVATION

TEMPERATURE OF THE

ANTIFREEZE FUNCTION

SETTINGS-ANTI FROZEN

DEACTIVATE

ANTI FROZEN

ACTIVATE

ANTI FROZEN