10

17

18

M

R

4

5

6

32

5-HYDRAULIC CONNECTION

HYDRAULIC KIT

The boiler comes with a complete kit for the production of domestic water, comprising:

A plate heat exchanger

A three-way diverter valve

A flow switch

Pipes and fittings for connection

The kit is designed to heat domestic water directly from the domestic water supply system. The manufacturer supplies the kit ready

assembled.

When the tap is turned on and hot water is needed, the internal water flow switch will send a signal to the diverter valve to channel the

hot water from the boiler to the plate heat exchanger. The temperature of the domestic water depends a great deal on the temperature of

the water inside the heating system. This can be calculated to a good degree of accuracy by taking 10°-15°C away from the value shown

on the control panel of the boiler (which is the temperature of the water in the boiler).

If domestic water is needed while the boiler is in ECOSTOP mode, the boiler will automatically and immediately begin the start-up process

to heat the water inside the boiler, followed by the domestic water after 30 seconds.

1

DRAIN TAP

2

SAFETY VALVE

3

FILLING TAP

4

DOMESTIC WATER OUTLET

5

DOMESTIC WATER INLET

6

HEATING RETURN

7

HEATING DELIVERY

8

-------------

9

FLOW METER

10

3-WAY VALVE MOTOR

11

EXCHANGER

12

PRESSURE SWITCH

13

PRESSURE GAUGE CONNECTIONS

14

-------------------------------

15

EXPANSION VESSEL CONNECTIONS

16

PUMP

17

EXCHANGER DELIVERY

18

EXCHANGER RETURN

NOTE: FOR THE POSITIONS, PLEASE SEE THE DRAWING

ON THE PREVIOUS AND NEXT PAGE AS WELL