5-EMERGENCY PANEL
Technical Dept. - All rights reserved - Reproduction is prohibited
FEED SCREW LOADING
This function can only be activated when the product is off and allows the pellets to be loaded into the loading system (feed screw). It
can be used each time it runs out of pellets in the hopper (see alarm A02). It is useful to prevent failed start-ups (alarm A01) due to the
hopper being empty.
The FEED SCREW LOADING function is activated as follows (with the product off): bring selector “D” on the emergency panel to OFF and
press key TEST on the same panel for three consecutive times. Wait a few seconds and FEED SCREW will flash on the display.
Press the TEST key once again when the pellets begin to fall into the brazier to end the LOAD FEED SCREW function and proceed with the
product start-up.