Installation and assembly – MCZ Boxtherm 60 Pellet User Manual
Page 17

15
3-INSTALLATION AND ASSEMBLY
TECHNICAL CHARACTERISTICS
BOXTHERM 60 PELLET
Fuel type
Pellets
Nominal output power
6.1 kw (5246 kcal /h)
Minimum output power
2.4 kw (2064 kcal/h)
Efficiency at Max
91,7%
Efficiency at Min
93%
Temperature of exhaust smoke at Max
150 °C
Temperature of exhaust smoke at Min
67 °C
Particulate/OGC/Nox (13% O
2
)
27 mg/Nm
3
- 7 mg/Nm
3
- 119
mg/Nm
3
CO at 13% O
2
at Min and at Max
0,03 – 0,01%
CO
2
at Min and at Max
4,1% - 6,4%
Recommended draught at Max power
0.10 mbar - 10 Pa
Recommended draught at Min power
0.05 mbar - 5 Pa
Mass of smoke at Max
6.5 g/sec
Hopper capacity
13 litres
Type of pellet fuel
Pellet diameter 6-8 mm and size 5/30 mm
Pellet hourly consumption
Min ~ 0.6 kg/h* - Max ~ 1.25 kg/h*
Autonomy
At min ~ 14 h* - At max ~ 7 h*
Heatable volume m
3
131/40 – 150/35 – 175/30 **
Combustion air inlet
External diameter 50 mm
Smoke outlet
External diameter 80 mm
Air inlet
80 cm
2
Electrical power consumption
Max 320 W - Med. 100 W
Supply voltage and frequency
230 Volt / 50 Hz
Net weight
80 kg
Weight with packaging
90 kg
* Data that may vary depending on the type of pellets used.
** ** Heatable volume based on the heat demand of cal/m
3
40-35-30 (respectively 40-35-30 Kcal/h per m
3
).
Tested according to EN 14785 accordance with Directive 89/106/EC (Construction Products).
Technical Dept. - All rights reserved - Reproduction is prohibited