Error Messages

When you turn on the fixture, it will make a reset first. The display may show “XXer”

while there are problems with one or more channels. “XX” stands for the channel

equipped with a testing sensor for positioning.

For example,

when the display shows “03Er”, it means there is some error in channel 3. If

there are some errors on channel 1, channel 2, channel 3 at the same time, you may see the

error message “01Er”, “02Er”,”03Er” flash repeatly for 5 times, and then the fixture will

generate a reset signal, all the stepper motors will reset. If the error messages maintain after

performing reset more than 3 times, it will detect whether the fixture has more than 3 errors.

If the fixture has more than 3 errors (including 3 errors), all the channels can not work

properly; but if the fixture has less than 3 errors, only the channels which have errors can not

work properly, others can work as usual.

01Er:

(Color-wheel error) This message will appear after the reset of the fixture if the

magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the

stepping-motor is defective (or its drive circuit on the main PCB). The color wheel is not

located in the default position after the reset.

07Er:

(Effect-wheel error) This message will appear after the reset of the fixture and if the

magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the

stepping-motor is defective (or its driver circuit on the main PCB). The effect-wheel is not

located in the default position after the reset.

08Er:

(Zoom-error) This message will appear after the reset of the fixture and if the

magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the

stepping-motor is defective (or its driver circuit on the main PCB). The zoom is not located in