beautypg.com

Default settings are shaded – Elation Professional CMY Zoom 250 User Manual

Page 19

background image

CMY ZOOM 250

©Elation Professional® Los Angeles, Ca. 90058 - CMY ZOOM 250™

-

-

Control Board

The control panel located on the top of the fixture allows you to access the main menu and

make all necessary adjustments to the CMY ZOOM 250™. During normal operation, tapping

the “MODE” key once will access the fixture’s main menu. Once in the main menu you can

navigate through the different functions and access the sub-menus with the Up and Down

buttons. Once you reach a field that requires adjusting, tap the ENTER button to activate that

field and use the UP and Down button to adjust the field. Tapping the Enter button once

more will confirm your setting. Once a setting is saved the LED will briefly readout PASS to

confirm a new setting has been made and locked into memory. You may exit the main menu

at any time without making any adjustments by tapping the EXIT button.

Default settings are shaded.

1

ADDR

A001~A511

Indicates the staring DMX address
A001 also is the setting for slave

2

TEST

T-01~T-XX

Automatically test the function

MSTR

Runs fixture as “master” for audio

3

AUDI

ALON

Runs fixture as “alone” for audio

4

LAMP

ON/OFF

Manually switches lamp “on” and “off”

ALL

ON/OFF

Reset all motors and returns fixture to
home

COLR

ON/OFF

Reset only motors for colors

SHTR

ON/OFF

Reset only motors for shutter and/or
dimmer

5

RESE

OTHR

ON/OFF

Reset other motors

LIFE

0000~9999

Displays the total fixture running time

LAMP

0000~9999

Displays a lamps running time

6

TIME

CLMP

ON/OFF

Clear lamp running time

7

RDIM

ON/OFF

Reverses the dimmer

VALU

D–XX D-00 (DXXX)

Display the DMX512 value of each
channel

D ON

ON/OFF

Display turn off after 2mins

8

DISP

FLIP

ON/OFF

This function will reverse the display 180

LAAU

ON/OFF

Automatic lamp start with power

DLOF

ON/OFF

Switch lamp via DMX

DLAY

D–XX D-15

Lamp on delay time

SPOT

ON/OFF

Lamp optimization

DFSE

ON/OFF

Resets all the fixture functions to default

9

SPEC

VER

V1.0~V9.9

Software version

STEP

S–01 ~S–48

Set the amount of your program

C–01

0 1 XX(00~FFH)

10

EDIT

SCXX

:

: