The air piston does not operate.
1. Release trigger momentarily and re-apply.
2. Tap the top of the air cylinder using the palm of your hand. Do not use a hammer, timber,
or anything else which may damage the cylinder.
3. Piston may be frozen, see below.
4. Re-adjust regulator to increase air pressure.
1. Piston may be frozen due to excess water in the air line supply.
2. Release the trigger for a few minutes and allow the pump to thaw.
3. Fit a filter or filter/lubricator to reduce the water content in the air supply.
The air piston stalls.
Frost on air cylinder - air piston stalled.
1. The air pressure is too low.
2. The minimum recommended air pressure is 30psi.
4. TROUBLESHOOTING
5. PARTS
Air Pressure Regulator: ............................................. 0-6 bar
Air Inlet: .................................................................. 1/4” BSP
Maximum Air Pressure: .............................................100 psi
Minimum Air Pressure: ................................................30 psi
Air Consumption: .......................................................4.4 cfm
Maximum sound level at 1 metre: ............................... 74 dB
3. SPECIFICATION
Item
Part No.
Description
1
151/Z950-500
Complete pick-up pipe
2
TP90.01
Complete casing
3
TP90.02
Screw for casing
4
TP90.03
Knurled ring
5
TP90/REG
Regulator assembly
-
TP90HK
Hose kit - 2 metres (optional-not shown)
Original Language Version
TP90.V2 Issue: 2 - 12/01/10