InstructIons for:

PROFESSIONAL AIR REguLAtOR, FILtER,

LuBRICAtOR RANgE

MoDEL no's:

SA306, SA306FR, SA306L, SA306F, SA306R.

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and

properly maintained, give you years of trouble free performance.

1. SAFEtY INStRuCtIONS

IMPORTANT: PLEASE READ tHESE INStRuCtIONS CAREFuLLY. NOtE tHE SAFE OPERAtIONAL REQuIREMENtS, WARNINgS & CAutIONS.

uSE tHE PRODuCt CORRECtLY AND WItH CARE FOR tHE PuRPOSE FOR WHICH It IS INtENDED. FAILuRE tO DO SO MAY CAuSE

DAMAgE AND/OR PERSONAL INJuRY AND WILL INVALIDAtE tHE WARRANtY. PLEASE KEEP INStRuCtIONS SAFE FOR FutuRE uSE.

WARNINg! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.

WARNINg! Disconnect the equipment from the air supply before changing accessories,servicing or performing any maintenance.

Keep the equipment clean and maintain it in good condition (use an authorised service agent).

replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

WARNINg! Ensure that the correct air pressure is maintained and not exceeded.

Keep air hoses away from heat, oil and sharp edges. check hoses for wear before each use and ensure that all connections are secure.

DO NOt direct air from the air hose at yourself, others or animals.

DO NOt operate air tools when tired or under the influence of drugs, alcohol or intoxicating medication.

Drain the compressor air tank and the filter bowl daily. Water in the air line will damage your equipment.

When work is complete ensure that the air supply is turned off.

2.1. Introduction

suitable for industrial workshop air supply set-ups where high flow applications are required. state of the art design for the professional user.

regulator assemblies feature locking control knob for pre-setting air pressure and an easy-to-read digital pressure gauge. fitted with

manual drain facility. Both filters and lubricators are fitted with metal bowl cages for protection.

2.2. Specifications

2. INtRODuCtION & SPECIFICAtIONS

Filter/Lubricator/Regulator - SA306

Max. inlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174psi

Max. outlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 145psi

Max. flow rate @ 100psi . . . . . . . . . . . . . . . . . . . . . . . 63.5cfm

Lubricant . . . . . . . .sealey Air tool oil - Ato/500 or Ato/1000

Ports:Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¼”BsP

outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¼”BsP

WARNINg! Filter and lubricator bowls are manufactured

from polycarbonate and must not be used at temperatures

over 140°F (60°C) or for pressures over 170psi (12bar).

Polycarbonate can be damaged and may fail if exposed to

certain solvents either internally or externally, such as

strong alkalies, compressor oils containing aromatic

hydrocarbons or fire retardant oils, or the fumes of any of

these. Clean with warm water only.

SA306

SA306FR

SA306F

SA306L

SA306R

Original Language Version

sA306/306f/306fr/306L/306r Issue: 1 - 30/07/12

Filter - SA306F

Max. inlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174psi

Max. outlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 145psi

Max. flow rate @ 100psi . . . . . . . . . . . . . . . . . . . . . . . . .74cfm

Ports:Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¼”BsP

outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¼”BsP

Filter/Regulator - SA306FR

Max. inlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174psi

Max. outlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 145psi

Max. flow rate @ 100psi . . . . . . . . . . . . . . . . . . . . . . . 63.5cfm

Ports:Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¼”BsP

outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¼”BsP

Lubricator - SA306L

Max. inlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174psi

Max. outlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 145psi

Max. flow rate @ 100psi . . . . . . . . . . . . . . . . . . . . . . . 77.5cfm

Lubricant . . . . . . . .sealey Air tool oil - Ato/500 or Ato/1000

Ports:Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¼”BsP

outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¼”BsP

Regulator - SA306R

Max. inlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174psi

Max. outlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 145psi

Max. flow rate @ 100psi . . . . . . . . . . . . . . . . . . . . . . . . .60cfm

Ports:Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¼”BsP

outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¼”BsP