beautypg.com

Ericsson LBI-39169 User Manual

Page 27

background image

MONITORING EDACS FAULT CONDITIONS

LBI-39169

27

Table 1 - Status Colors/Levels

Category

Status

Condition

Status Meaning

Icon Color

Administrative

Unmanaged

Users can set this value, which indicates that

the object should not be monitored and that the
status should be ignored. When the user sets
the object back to “managed.” the EDACS-
>Fault->Update operation must be performed.

Off-white

Administrative

Testing

An application sets the status to “testing” when

an object is undergoing temporary diagnostic
or maintenance procedures. This category is
not used by the EDACS Network Manager
application.

Salmon

Administrative

Restricted

An application sets the status to “restricted”
when a valid associated CEC/IMC/RCEC/SG
node license does not exist for this element.

Tan

Administrative

Shutdown

An application sets the status to “shutdown”
when an object is inactive (although there may
not be anything necessarily wrong with the
object). This category is not used by the
EDACS Network Manager application.

Dark Brown

Operational

Unknown

An application sets the status to “unknown”
when the status of an object cannot be
determined. EDACS icon may be blue if there
is another icon with the same Network Number
and Node Number or if polling does not detect
a physical device corresponding to this icon.

Blue

Operational

Normal

An application sets the status to “normal” when
the object is in a normal operational state.

Green

Operational

Warning

An application sets the status to “warning”

when an object may face a potential problem.

Cyan

Operational

Minor/

Marginal

An application sets the status to
“minor/marginal” when an object has a minor
problem; this status should not, however,
impede the normal operation of the network.

Yellow

Operational

Major

An application sets the status to “major” when
an object has serious problems; these
problems are likely to impede normal use of
the network.

Orange

Operational

Critical

An application sets the status to “critical” when
a device is not functioning or is not accessible
by the EDACS Network Manager.

Red