1) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work
without shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your
home. Place the main power switch in the “OFF”
position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker
switch(s), that control the power to the fixture or room
that you are working on.
c) Place the wall switch in the “OFF” position. If the fixture
to be replaced has a switch or pull chain, place those in
the “OFF” position.
2) Find the appropriate threaded holes on mounting strap.
Assemble mounting screws into threaded holes.
3) Attach mounting strap to outlet box.
4) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a hole
and two raise dimples. Wrap ground wire from outlet
box around green ground screw, and thread into hole.
B) On fixtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture
ground wire to outlet box ground wire with wire connector.
(Not provided.) After following the above steps. Never connect
ground wire to black or white power supply wires.
5) Make wire connections (connectors not provided.) Reference
chart below for correct connections and wire accordingly.
6) Push fixture to wall. Place canopy of fixture over tabs on
mounting bracket.
NOTE: Be certain wires do not get pinched between canopy
and mounting strap.
7) Thread one screw into hole on top and bottom of canopy.
Tighten screws to secure fixture in place.
8) Insert recommended bulb.
9) Carefully set glass down inside cage. Press bracket on cage
down against inside of glass.
10) Raise cage with glass up to fixture. Pass threaded studs on
cage up through holes in roof of fixture.
11) Screw threaded caps onto threaded studs. Tighten threaded
caps to secure cage to fixture. (DO NOT over tighten.)
Date Issued: 10/31/14
IS-45133-US
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black
White
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
We’re here to help
866-558-5706
Hrs: M-F 9am to 5pm EST
MOUNTING STRAP
PLANCHA PARA
MONTAR
SCREW
TORNILLO
CAGE
JAULA
GLASS
VIDRIO
THREADED STUD
PERNO PRISIONERO
ROSCADO
THREADED CAP
TAPA ROSCADO
SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.
TAB
LENGÜETA
BRACKET
SOPORTE
CAGE WITH GLASS
JAULA CON VIDRIO