SAFETY INSTRUCTIONS

READ THIS FIRST

KEEP THESE INSTRUCTIONS

This fixture is intended for installation in accordance with the National

Electric Code (NEC) and Local code specifications. Failure to adhere to

these codes and instructions may result in serious injury and/or property

damage and will void the warranty.

WARNING – RISK OF ELECTRIC SHOCK

• Do not mount luminaire within 10 feet (3m) of a swimming pool, spa or

fountain.

• This fixture is to be used only with a Kichler

®

low voltage lighting power

unit (transformer) rated a maximum 15 volts, 300 W per secondary (25 AMPS)

NOTE: If additional Direct Burial wire is needed, contact your local Kichler

®

landscape distributor.

• 8 GA wire can be purchased in length of 250’ (76 M), 15503-BK.

• 10 GA wire can be purchased in length of 250’ (76 M), 15504-BK.

• 12 GA wire can be purchased in lengths of 100’ (30 M), 15501-BK; 250’

(76 M), 15502-BK; 500’ (152M), 15505-BK; and 1000’ (304 M), 15506-BK.

Date Issued: 1/13/12

IS-16030-US

For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page

Para informacion de la garantia por favor visite: www.landscapelighting.com/portal/warranty_page

SPHERE

RETAINING

SCREWS

TORNILLOS DE

RETENCIÓN DE

LA ESFERA

GLASS

SEALING RING

ANILLO

OBTURADOR

DE VIDRIO

GLASS

VIDRIO

GASKET

JUNTA

SPHERE

ESFERA

THREADED STAKE

ESTACA ROSCADA

FIXTURE ASSEMBLY AND INSTALLATION

1. Turn off power.

2. Determined desired location of fixture and dig hole. Hole should be 9"

(diameter) x 6" (deep) if working in soft soil, such as sand. If working in

hard or compacted soil, such as clay, dig a 9" (diameter) x 10" (deep) hole.

3. If installing in soft soil: Use the threaded stake to dig into the ground

and temporarily stabilize the fixture.

If installing in hard soil: Fill the bottom of the hole with approximately 3"

(76mm) of pea gravel. Place the fixture in hole and back fill around the

fixture with soil, up to the wire exit hole.

4. Make wire connections using supplied Quic Disc™ following the instructions

below, or using other approved wiring connection method (not supplied.)

The fixture wire is not intended for direct burial. According to the requirements

of the National Electric Code (NEC), direct burial rated wire is to be buried

a minimum of 6" [152mm] beneath the surface of the ground.

5. To aim the beam: Remove the glass sealant ring by removing the six (6)

screws on top of the fixture. Loosen the screws on the sphere retaining

ring until the sphere becomes unfixed. Aim the beam as desired. (up to

15°) Re-tighten the screws on the sphere retaining ring until the sphere is

secure and does not rotate. Clean sealing surface, and replace glass,

gasket, and glass sealing ring. Install and torque screws in triangular

pattern, following the numbers screws holes 1-6.

6. Back fill around the fixture with soil.

SOIL

SUELO

FOR INSTALLATION IN SOFT SOILPARA

INSTALACIÓN EN SUELOS BLANDOS

SOIL

SUELO

FOR INSTALLATION IN HARD SOIL

PARA INSTALACIÓN EN SUELOS DUROS

3" (76 MM)

OF PEA GRAVEL

3” (76 MM) DE

GRAVA DE RÍO

START

INICIO

TIGHTEN SCREWS IN TRIANGULAR PATTERN SHOWN ABOVE.

AJUSTE LOS TORNILLOS EN FORMA TRIANGULAR TAL COMO SE

MUESTRA ANTERIORMENTE.

QUIC DISC

WIRING INSTRUCTIONS

Turn off power.

The full length of the 18 GA fixture wire may be used to connect with the 10 GA or 12 GA cable provided the following conditions are met:

• Wiring is to be protected by routing close to the fixture or accessory or secured to a building structure such as house or deck.

• 18 GA fixture wiring is to be cut off so that it is attached to the connector within 6 inches of the fixture or building structure.

• If it is necessary to make the connections underground, then no more than 6 inches of the 18 GA fixture wire is to be buried.

The Quic Disc

connector is designed to install one fixture and accommodates one 18 GA fixture wire and one 10 GA or one 12 GA supply wire.

Place the 10 gauge supply wire across the area marked 10 GA on Quic Disc

or place the 12 gauge supply wire across the area marked 12 GA

on Quic Disc

.

Place the 18 gauge fixture wire across the area marked 18 GA on the Quic Disc

. After the wires are in place, connecta the top of the Quic

Disc

to the base with supplied screw, making sure that the wires remain flat in the bottom portion of the Quic Disc

, and the screw is tightened

all the way down.

The copper contacts will automatically pierce the wires’ insulation. Excess 18 GA fixture wire that sticks out the end of the Quic Disc

is to be cut off.

Make no other wiring connections to the 18 GA fixture wire.