INSTRUCTIONS PERTAINING TO A RISK OF FIRE,OR INJURY TO

PERSONS

IMPORTANT SAFETY INSTRUCTIONS

Lighted lamp is HOT!

WARNING — To reduce the risk of FIRE OR INJURY TO PERSONS.

1) Turn off / unplug and allow to cool before replacing lamp.

2) Lamp gets HOT quickly! Contact only switch / plug when turning on.

3) Do not touch hot lens or cowl.

4) Do not remain in light if skin feels warm. (Light is intense, it may cause

“sunburn”.)

5) Do not look directly at lighted lamp.

6) Keep lamp away from materials that may burn.

7) Use only with wattage and lamp marked on fixture.

8) Do not touch the inner glass envelope of the lamp at any time. Use a soft cloth.

Oil from skin may damage lamp.

9) Do not operate the fixture with a damaged or missing lens.

SAFETY INSTRUCTIONS

READ THIS FIRST

KEEP THESE INSTRUCTIONS

This fixture is intended for installation in accordance with the National

Electric Code (NEC) and Local code specifications. Failure to adhere to

these codes and instructions may result in serious injury and/or property

damage and will void the warranty.

1) WARNING: This fixture is not to be installed within 10 feet (3M) of a pool,

spa or fountain.

2) This fixture is to be used only with a power unit (transformer) rated a maximum

of 300 W (25 AMPS) 15 volts.

3) According to the requirements of the National Electric Code (NEC), direct

burial rated wire is to be buried a minimum of 6” [152mm] beneath the

surface of the ground.

NOTE: If additional Direct Burial wire is needed, contact your local

Kichler

®

landscape distributor.

• 8 GA wire can be purchased in length of 250’ (76 M), 15503-BK.

• 10 GA wire can be purchased in length of 250’ (76 M), 15504-BK.

• 12 GA wire can be purchased in lengths of 100’ (30 M), 15501-BK; 250’

(76 M), 15502-BK; 500’ (152M), 15505-BK; and 1000’ (304 M), 15506-BK.

4) Fixture shall not use a tungsten halogen lamp unless the fixture is marked

for use with such lamps.

5) Wiring connections must be made with approved/listed wire connection

device(s) suitable for the application. Do not exceed manufacturers’ wiring

combination specifications for size and quantity of conductors.

CAUTION

WHEN INSTALLING KICHLER LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW VOLTAGE),
CARE SHOULD BE TAKEN TO KEEP CLEAR OF POTENTIALLY COMBUSTIBLE MATERIALS.
WHEN MAINTAINING THE FIXTURES, BE SURE TO REMOVE LEAVES, PINE NEEDLES,
GRASS CLIPPINGS, MULCH, OR ANY DEBRIS THAT HAS ACCUMULATED ON THE LIGHT
BULB, LENS, OR BODY OF THE FIXTURE.

ACCENT LIGHT ASSEMBLY - FIXTURE IS SUITABLE FOR OUTDOOR USE ONLY

NOTE: Cable supplied with fixture is not to be run through wall. Reference

local electrical codes if this type of installation is required.

1) Secure mounting bracket to surface using the stainless steel hanger bolts

provided. (Never use copper or brass screws)

A) When securing mounting bracket to a vertical surface be sure that

slot on mounting bracket is facing downward.

B) When securing mounting bracket to a horizontal surface, arrange

slot in best accessible direction for power supply wire.

NOTE: Direction of accent light must be below horizontal.

2) Thread accent light into mounting bracket making certain that wire is in slot

on mounting bracket. Secure in place with locknut.

3) Apply silicone lubricant (provided) over o-ring(s).

4) Install lamp (not supplied) into socket inside accent light.

NOTE: Use caution when assembling. Hold lamp by outer housing.

DO NOT touch glass envelope inside. If this happens, clean bulb with

denatured alcohol and a lint free cloth.

5) Assemble cowl to accent body. Secure in place using provided thumb screw.

6) Make wire connections using supplied Quic Disc

following instructions

below, or using other approved wiring connection method (not supplied.)

Date Issued: 12/2/11

IS-15087-US

For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page

Para informacion de la garantia por favor visite: www.landscapelighting.com/portal/warranty_page

QUIC DISC

WIRING INSTRUCTIONS

Turn off power.

The full length of the 18 GA fixture wire may be used to connect with the 10 GA or 12 GA cable provided the following conditions are met:

• Wiring is to be protected by routing close to the fixture or accessory or secured to a building structure such as house or deck.

• 18 GA fixture wiring is to be cut off so that it is attached to the connector within 6 inches of the fixture or building structure.

• If it is necessary to make the connections underground, then no more than 6 inches of the 18 GA fixture wire is to be buried.

The Quic Disc

connector is designed to install one fixture and accommodates one 18 GA fixture wire and one 10 GA or one 12 GA supply wire.

Place the 10 gauge supply wire across the area marked 10 GA on Quic Disc

or place the 12 gauge supply wire across the area marked 12 GA

on Quic Disc

.

Place the 18 gauge fixture wire across the area marked 18 GA on the Quic Disc

. After the wires are in place, connecta the top of the Quic

Disc

to the base with supplied screw, making sure that the wires remain flat in the bottom portion of the Quic Disc

, and the screw is tightened

all the way down.

The copper contacts will automatically pierce the wires’ insulation. Excess 18 GA fixture wire that sticks out the end of the Quic Disc

is to be cut off.

Make no other wiring connections to the 18 GA fixture wire.

CORRECT

CORRECTO

MOUNTING BRACKET

CONSOLA DE MONTAJE

STAINLESS STEEL SCREW

TORNILLO DE ACERO INOXIDABLE

LOCKNUT

TUERCA DE SEGURIDAD

ACCENT BODY

CUERPO DE ACENTO

O-RING

ANILLO

EN O

THUMB SCREW

TORNILLO DE APRIETE

MANUAL

SCREEN

DEFENSA

COWL

CAPUCHA

SLOT