MOUNTING STRAP
ABRAZADERA DE MONTAJE
1) Pass wire through threaded pipe. Screw end of threaded
pipe with hexnut into coupling on top of fixture body.
2) Pass wire through tube. Lower tube down over threaded pipe.
3) Pass wire through hole in check ring. Pass hole in check ring
over end of threaded pipe. Set check ring on top of tube.
4) Pass wire through hole in top trim. Pass hole in top trim over
end of threaded pipe. Set top trim on top of check ring.
5) Pass wire through coupling. Thread coupling onto threaded pipe.
6) Pass wire from fixture through stem and screw stem into
coupling on top of fixture body.
NOTE: Thread locking compound must be applied to all
stem threads as noted with symbol (3) to prevent accidental
rotation of fixture during cleaning, relamping, etc.
7) Pass fixture wire through remaining stems and screw stems
together.
8) If using swivel for sloped ceilings, pass fixture wire through
swivel and thread swivel onto top of last stem.
9) Thread small threaded pipe into end of swivel.
10) Pass threaded pipe on end of swivel up through hole in
canopy.
11) Slip large flat washer then lockwasher over end of threaded
pipe protruding from inside of canopy. Thread hexnut onto
threaded pipe. Tighten hexnut to secure swivel to canopy.
NOTE DIRECTION OF SWIVEL IN ACCORDANCE WITH
CEILING.
12) If not using swivel, thread small threaded pipe into end of
last stem.
13) Pass threaded pipe on end of stem up through hole in
canopy.
14) Slip lockwasher over end of threaded pipe protruding from
inside canopy. Thread hexnut onto threaded pipe. Tighten
hexnut to secure stem to canopy.
15) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work
without shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your
home. Place the main power switch in the “OFF”
position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker
switch(s), that control the power to the fixture or room
that you are working on.
c) Place the wall switch in the “OFF” position. If the fixture
to be replaced has a switch or pull chain, place those in
the “OFF” position.
16) Find the appropriate threaded holes on mounting strap.
Assemble mounting screws into threaded holes.
17) Attach mounting strap to outlet box. (Screws not provided).
Mounting strap can be adjusted to suit position of fixture.
18) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a
hole and two raised dimples. Wrap ground wire from
outlet box around green ground screw, and thread into
hole.
B) On fixtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture
ground wire to outlet box ground wire with wire connector.
(Not provided.) After following the above steps. Never
connect ground wire to black or white power supply wires.
19) Make wire connections (connectors not provided.) Reference
chart below for correct connections and wire accordingly.
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black
White
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
Date Issued: 10/12/12
IS-43262-US
CANOPY
ESCUDETE
STEM
VÁSTAGO
KNURL KNOB
PERILLA ESTRADA
3
SWIVEL
UNIÓN GIRATORIA
3
3
20) Push fixture to ceiling, carefully passing mounting screws
through holes in canopy.
21) Thread knurl knobs onto mounting screws. Tighten knurl
knobs to secure fixture to ceiling.
22) Thread short end of long threaded pipe with hexnut into
coupling on bottom of fixture body.
23) Pass hole in flat washer over end of threaded pipe. Pass hole
in rubber washer over end of threaded pipe.
24) Raise inner glass shade up to fixture. Fit inner glass shade
inside cage.
25) Pass hole in inner glass shade over end of threaded pipe.
26) Slip hole in rubber washer over end of threaded pipe. Slip
hole in flat washer over end of threaded pipe.
27) Screw hexnut onto threaded pipe. Tighten hexnut up against
flat washer.
28) Pass hole in bottom trim over end of threaded pipe.
29) Screw finial onto end of threaded pipe. (DO NOT over tighten.)
FINIAL
REMATE
RUBBER WASHER
ARANDELA DE CAUCHO
FLAT WASHER
ARANDELA PLANA
THREADED PIPE
TUBO ROSCADO
HEXNUT
TUERCA HEXAGONAL
BOTTOM TRIM
GUARNICIÓN INFERIOR
INNER GLASS SHADE
PANTALLA DE VIDRIO
INTERIOR
CAGE
JAULA
TUBE
TUBO
FLAT WASHER
ARANDELA PLANA
RUBBER WASHER
ARANDELA DE CAUCHO
THREADED PIPE
TUBO ROSCADO
COUPLING
ACOPLAMIENTO
SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.
CHECK RING
ANILLO DE SEGURIDAD
TOP TRIM
GUARNICIÓN SUPERIOR