Kichler 42427 User Manual
Kichler Lighting
If fixture is provided with ground wire. Connect fixture ground
wire to outlet box ground wire with wire connector, (not provided)
after following the above steps. Never connect ground wire to
black or white power supply wires.
13) Make wire connections (connectors not provided.) Reference
chart below for correct connections and wire accordingly.
14) Push fixture to ceiling, carefully passing threaded pipe
through hole.
15) Secure fixture to ceiling with finial.
16) Set glass over sockets.
17) Thread socket ring onto socket. (DO NOT over tighten.)
18) Insert recommended bulb. CAUTION: DO NOT touch bulb
with bare hands. If this happens, clean bulb with denatured
alcohol and a lint free cloth.
19) Slip glass sleeve over bulb.
LOOP/CHAIN LINK MOUNT
1) Follow steps 1 and 2 from Stem Mount Instructions.
2) Screw threaded pipe into end of each stem.
3) Screw loops onto end of each threaded pipe.
4) Add one chain link to each loop and add second loop to each
chain link.
5) Screw threaded pipe into end of each loop.
6) Place spacers over end of each threaded pipe.
7) Pass each threaded pipe on loops through holes in canopy.
8) Follow steps 5 - 19 from Stem Mount Instructions.
IMPORTANT SAFETY INSTRUCTIONS
LIGHTED BULB IS HOT!
WARNING: To reduce the risk of FIRE or INJURY TO PERSON:
• Turn off and allow to cool before replacing bulb.
• Bulb gets HOT QUICKLY! Contact switch only when turning off.
• DO NOT remain in light if skin feels warm. (Light is intense,
may cause “sunburn”)
• DO NOT look directly at lighted bulb.
• Keep materials away from bulb that may burn.
• Use ONLY with wattage specified or lower.
• DO NOT touch bulb at any time, use a soft cloth. Oil from skin
may damage bulb.
• DO NOT operate fixture with missing or damaged glass.
RIGID STEM MOUNT
1) Pass wire through stems and screw stems into couplings on
top of fixture body. NOTE: Thread locking compound must be
applied to all stem threads as noted with symbol (3) to prevent
accidental rotation of fixture during cleaning, relamping, etc.
2) Pass fixture wire through remaining stems and screw stems
together.
3) Place spacers onto end of each stem.
4) Pass holes in canopy over ends of stems.
5) Slip one lockwasher over end of each stem.
6) On one stem screw hexnut onto end of stem.
7) On other stem slip end of safety cable then remaining lockwasher
over end of stem. Screw hexnut onto stem.
8) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work
without shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your
home. Place the main power switch in the “OFF”
position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker
switch(s), that control the power to the fixture or room
that you are working on.
c) Place the wall switch in the “OFF” position. If the fixture
to be replaced has a switch or pull chain, place those in
the “OFF” position.
9) Thread hexnut onto threaded pipe so that 5 threads are
exposed above hexnut. Thread that end of the threaded
pipe into mounting strap and tighten hexnut against
mounting strap. Screw second hexnut onto end of threaded
pipe protruding from back of mounting strap.
10) Attach mounting strap to outlet box. (Screws not provided.)
11) Attach safety cable to slot in mounting strap.
12) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a hole
and two raise dimples. Wrap ground wire from outlet box
around green ground screw, and thread into hole.
B) On fixtures where a cupped washer is provided. Put ground
wire from outlet box under cupped washer and green
ground screw and thread screw into hole in mounting strap.
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black
White
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
IS-42427-US
Date Issued: 12/28/12
LOOP/CHAIN LINK
LAZO/ ESLABÓN DE CADENA
MOUNTING STRAP
PLANCHA PARA MONTAR
GLASS
VIDRIO
CANOPY
ESCUDETE
STEM
VARILLA
4
3
SPACER
ESPACIADOR
LOOP
ANILLO
CHAIN LINK
ESLABÓN DE
CADENA
THREADED PIPE
TUBO ROSCADO
THREADED PIPE
TUBO ROSCADO
RIGID STEM MOUNT
MONTAJE DEL VÁSTAGO NERVADO
3
3
SAFETY CABLE
ACTIVACIÓN DE SEGURIDAD
HEXNUT
TUERCA HEXAGONAL
FINIAL
CAPUCHON
FIXTURE BODY
CUERPO DEL ARTEFACTO
HEXNUT
TUERCA HEXAGONAL
LOCKWASHER
ARANDELA DE SEGURIDAD
BULB
BOMBILLA
GLASS SLEEVE
CAMISA DE VIDRIO
SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.
SOCKET RING
ANILLO DEL CASQUILLO