8.2.4
Adjustment of the bevelling angle (Fig. 10-11)
The support arm can be tilted vertically and in an angle of 45° to the left.
To be able to tilt the support arm, the bevel lock (16) must be released.
To prevent the bevel angle from changing while sawing, the locking knob of
the support arm must be tightened.
8.2.5
Mitre and width guide (Fig. 12-13)
The mitre and width guide (4) is mounted on the top saw table (1). The mitre and width guide
locking knob (5) must point towards the front of the machine.
The mitre and width guide is positioned over the saw blade guard (3). When the mitre and
width guide is installed, you must always make sure that the guide is fastened with the locking
knob.
Once the locking knob is released, the mitre and width guide (4) can be removed and the
switch (20) can be activated.
8.2.6
Connection to a dust collector
The dust of some types of wood (such as for instance beech, oak and ash)
can be hazardous if inhaled. Always use a dust collector:
If the saw is set up in an enclosed space;
Whenever the saw is being used for longer periods of time (more than a half hour per
day);
When sawing oak-, beech- or ashwood.
The dust collector must conform to the following requirements:
The diameter of the dust exhaust pipe must fit properly (43 mm);
The air flow volume must exceed 550m³/h;
The vacuum at the dust exhaust exit must be ≥ 740 Pa;
The air speed at the dust exhaust exit must be ≥ 20 m/s;
Follow the user instructions for the dust collector.
8.2.7
Connection to AC power
High-voltage!
Only operate this machine in dry surroundings.
This machine may only be connected to a power source that fulfils the following
requirements (also see the section "Technical data"):
- The mains voltage and the system frequency must conform to the voltage and frequency that
is indicated on the technical data sheet of the machine;
- Fusing protection with a residual current device (RCD), with a sensitivity of 30 mA.
- Sockets must be properly installed, earthed and tested.
Position a power cable in such a way that it does not hinder the work and cannot be
damaged.
Protect the power cable against heat, aggressive fluids and sharp edges.
Only use rubber-coated extension cables with a sufficient wire cross-section (3 x 1.5