Air inlet size

¼”

Avg. air consumption

170 l/min

Recommended hose diameter

9 mm

Container volume

1000 cc

Grit (blast media)

0.2-0.8 mm

Outlet nozzle (diameter)

5.4 mm

Compressed air quality

Cleaned and condensate-free

13

NOISE

Noise emission values measured according to relevant standard.
LpA (Sound pressure level):

<70 dB(A)

ATTENTION! The sound power pressure may exceed 85 dB(A), in this
case individual hearing protection must be worn.

aw (Vibration):

<2.5 m/s²

14

CLEANING AND MAINTENANCE

14.1 Cleaning

Regular maintenance and care is essential in preventing friction and corrosion
damage to the tool.

To protect against dirt, the tool should be covered with foil after each use. Should the
tool still be dirty, follow the following cleaning instructions:

Thoroughly clean the tool after disconnecting and releasing it from the compressed air

supply.

Clean the tool only with dry soft cloth or with compressed air

Never use caustic and/or abrasive cleaning agents.

Before storing the tool, lubricate the moving parts, especially the trigger, with a few
drops of special pneumatic oil.

14.2 Storage
Protect the tool from dust, dirt and the like. Cover the tool with foil to protect it from dirt and
resulting damage and malfunctioning.

14.3 Cleaning and servicing by qualified personnel
Maintenance work, not listed here, may only be carried out by an approved service centre.

15

FAULT DETECTION AND TROUBLESHOOTING

Problem

Possible cause

Action

The trigger is pressed
but the tool is not
functioning

Valve is defective.
Trigger is defective.

Consult an approved service
centre.