beautypg.com

Read reset, Mode switch – Casio PCR-365A User Manual

Page 81

background image

81

Convenient Operations and Setups

To print the hourly sales read/reset report

This report shows hourly breakdowns of sales.

OPERATION

REPORT

PGM

A-A08

Mode Switch

X

Z

CAL

REG

OFF

RF

PGM

8

1

a

8

1

a

PGM

A-A08

Mode Switch

X

Z

X

Z

CAL

REG

OFF

RF

PGM

Read

Reset

PGM

A-A08

Mode Switch

X

Z

CAL

REG

OFF

RF

PGM

8

2

a

8

2

a

PGM

A-A08

Mode Switch

X

Z

X

Z

CAL

REG

OFF

RF

PGM

Read

Reset

05-11-2000 17:30 0001
Z C01 000255

0002 HOURLY Z 0001

00:00-01:00 No 6
$4.50
01:00-02:00 No 25
$21.33
02:00-03:00 No 132
$90.78
23:00-24:00 No 1
$1.50
------------------------
TOTAL No 56
$1338.40

— Date/time/machine No.
— Read mode/clerk/consecutive No.

— Report code/report title/reset

symbol/reset counter

— Time range/No. of customers
— Sales amount

— Total No. of customers
— Total amount

05-11-2000 17:25 0001
Z C01 000254

0001 PLU Z 0001

PLU001 QT 16
0.24% $54.50
PLU002 QT 25
0.09% $21.33
PLU003 QT 132
0.12% $90.78
PLU200 QT 6
0.02% $4.50
------------------------
TOTAL QT 156
100% $21960.90

— Date/time/machine No.
— Read mode/clerk/consecutive No.

— Report code/report title/reset

symbol/reset counter

— PLU001/No. of items
— Sales ratio/PLU001 amount

— Total No. of items
— Total amount

To print the PLU/subdepartment read/reset report

This report shows sales for PLUs/subdepartments.

OPERATION

REPORT