Command 4 - conversion equation setup, Command 5 - data range setup – Casio EA-200 Technical Reference User Manual
Page 7

– 7 –
Command 4 - Conversion Equation Setup
{ 4, Equation Number, Equation Type, Number Format, Constants }
Equation Number
Equation Type
Number Format
Constants
* 0
Clear All equations.
* 0
Clear equation selected by the equation number parameter.
–––
–––
1
Equation 1 (Channel 1)
1
Polynomial
K
0
+K
1
X+K
2
X
2
+...+K
n
X
n
*
1
* 0
Standard
K
0
( , K
1
, ..., K
9
) *
3,4
2
Equation 2 (Channel 2)
2
Mixed polynomial
K
–m
X
–m
+...+K
–1
X
–1
+K
0
+K
1
X+......+K
n
X
n
*
2
10
Integer part (Decimal part cut off.)
K
–4
( , ..., K
–1
, K
0
, K
1
, ..., K
5
) *
3,4
3
Equation 3 (Channel 3)
3
Power
K
0
X
(K1)
+K
2
4
Modified power
K
0
K
1(X)
+K
2
5
Logarithmic
K
0
+K
1
In(X)
6
Modified logarithmic
K
0
+K
1
In(1/X)
7
Exponential
K
0
e
(K
1
X)
+K
2
K
0
( , K
1
, K
2
, K
3
) *
3,4
8
Modified exponential
K
0
e
(K
1
/X)
+K
2
9
Geometric
K
0
X
(K
1
X)
+K
2
10
Modified geometric
K
0
X
(K
1
/X)
+K
2
11
Reciprocal logarithmic [K
0
+K
1
In(K
2
X)]
–1
+K
3
12
Steinhart-Hart model [K
0
+K
1
(In 1000X)+K
2
(In 1000X)
3
]
–1
+ K
3
4
Equation 4 (SONIC channel)
* 0
Clear equation 4.
Unit
Temperature
1
Temperature used by distance conversion expression
* 0
°C (Celsius)
Temperature
1
°F (Fahrenheit)
( *20)
2
°C (Celsius)
3
K (kelvin)
4
°R (Rankin)
Channel Select
Data Select
Data Begin
Data End
Step
K
FFT Samples
* 0
Current send channel
* 0
Raw data
1 to 120000
1 to 120000
Data Range Steps
(*255)
1 to 13: Samples used
1
Channel 1
1
d/dt
(*1)
* 0: Last sample
–1: Data range number / K
(*6) 2
n
(2–8192)
2
Channel 2
2
d
2
/dt
2
(*1)
3
Channel 3
10
FFT-Real
4
SONIC channel
11
FFT-Imaginary
5
DIG IN channel
6
Recorded time data
10
Microphone
Command 5 - Data Range Setup
*1
Polynomial: Input constants in sequence, from n = 0 to 9.
*2
Mixed polynomial: Input constants in sequence from m = 4 to 1, and n = 0 to 5.
*3
Input of zero for constants can be skipped if all remaining constants are not used.
*4
Input 0 for constants that are not used.
•
When the conversion result of the “conversion equation” selected by Command 4 causes an overflow, the EA-200 sends a result of zero (0) to the calculator.
{ 5, Channel Select, Data Select, Data Begin, Data End, Step, K (, FFT Samples) }