beautypg.com

Analog, sonic sampling 3. post-processing – Casio EA-200 Technical Reference User Manual

Page 10

background image

– 10 –

Output Example

When the list is: 85(1010101), 34( 100010), 187(10111011), 204(11001100)

Following receipt of Command 3, output starts as soon as a Trigger Source is
generated.
The following can be specified as a Trigger Source.
0: None, 1: [Start] key, 10: Countdown, Command 8
Output is interrupted when the Start/Stop key is pressed.

Output is from Pin 1 of CH3.
Vout

Ϯ3V (Iout maximum 100mA)

Analog, SONIC Sampling

3. Post-Processing

(Operation 1–4, 7–10)

0 None (no calculation)

1 d/dt

2 d

2

/dt

2

10 FFT (Fast Fourier Transformation)-Real

11 FFT-Real, Imaginary

Calculation Methods

<>

(dx/dt)

n

= (X

n+1

– X

n–1

) / (2t)

(dx/dt)

1

= (X

2

– X

1

) / t

(dx/dt)

m

= (X

m

– X

m–1

) / t

x

n

: nth data

t:

Sampling period

m

:

Maximum value of n

<>

(d

2

x/dt

2

)

n

= (X

n+1

– 2

`

X

n

+ X

n–1

) / t

2

(d

2

x/dt

2

)

1

= (X

3

– 2

`

X

2

+ X

1

) / t

2

(d

2

x/dt

2

)

m

= (X

m

– 2

`

X

m+1

+ X

m–2

) / t

2

* First and second derivatives are supported only when timer is the sampling

trigger.

Mic

(Channel = 10)

0 Clear channel information.
1 Active

Analog Out, speaker

(Channel = 11, 12)

0

Clear channel information.

1–65535

Number of loops

Select Data

Select the data to be output by the sampling period.

0

List data

1

CH1 sampled values

2

CH2 sampled values

3

CH3 sampled values

10 Mic sampled values

Step

(Select Data 1, 2, 3, 10)

Number of steps for output sampled data
1, 2, 4, 8, 16

D8

D7

D6

D5

D4

D3

D2

D1

85

34

187

204

Clock