Command 4: conversion equation settings, Equation number, Equation type – Casio EA-200 Technical Reference User Manual
Page 14: Number format and unit, Constants and temperature

– 14 –
Command 4:
Conversion Equation Settings
{ 4, Equation Number, Equation Type, Number Format, Constants }
1. Equation Number
0 Clear all Command 4 data.
1 Specify CH1.
2 Specify CH2.
3 Specify CH3.
4 Specify SONIC channel.
2. Equation Type
Analog CH1, CH2, CH3
(Channel = 1, 2, 3)
Equation Name
Format
Restrictions
1
Polynomial
K
0
+K
1
X+K
2
X
2
+…+K
n
X
n
n = 0 to 9
2
Mixed Polynomial
K
–m
X
–m
+…+K
–1
X
–1
+K
0
+K
1
X+……+K
n
X
n
m = 1 to 4
n = 0 to 5
m+n > 0
X ≠ 0
3
Power
K
0
X
(K
1
)
+K
2
X > 0
4
Modified power
K
0
K
1
(X)
+K
2
K
1
> 0
5
Logarithmic
K
0
+K
1
In(X)
X > 0
6
Modified logarithmic
K
0
+K
1
In(1/X)
X > 0
7
Exponential
K
0
e
(K
1
X)
+K
2
8
Modified exponential
K
0
e
(K
1
/X)
+K
2
X ≠ 0
9
Geometric
K
0
X
(K
1
X)
+K
2
X > 0
10 Modified geometric
K
0
X
(K
1
/X)
+K
2
X > 0
11 Reciprocal logarithmic [K
0
+K
1
In(K
2
X)]
–1
+K
3
K
2
X > 0
12 Steinhart-Hart model
[K
0
+K
1
(In 1000X)+K
2
(In 1000X)
3
]
–1
+K
3
X > 0
SONIC
(Channel = 4)
0
Clear conversion equation.
1
Conversion equation temperature specification
3. Number Format and Unit
• Number Format
Analog CH1, CH2, CH3
(Channel = 1, 2, 3)
0
Standard
10 Integer part only
• Unit
SONIC
(Channel = 4)
0 °C (Celsius)
1 °F (Fahrenheit)
°F = (9/5) × °C + 32
2 °C (Celsius)
3 K (Kelvin)
4 °R (Rankin)
R = 1.8 × °C + 491.67
4. Constants and Temperature
• Constants
Analog CH1, CH2, CH3
(Channel = 1, 2, 3)
Polynomial: Input constants in sequence from Kn = 0
Mixed polynomial: Input constants in sequence from m= 4 to 1, n = 0 to 5.
• Temperature
SONIC
(Channel = 4)
Sound velocity is calculated from this value and unit.
Sound Velocity m/s = 331.5 + 0.6 × °C
Default sonic velocity is 343 m/s.