beautypg.com

Total counter reset, Access code, Total counter reset & access code – Everpure 2001 User Manual

Page 15: Suprema 2001 - operation & service manual

background image

SUPREMA 2001 - OPERATION & SERVICE MANUAL

Suprema 2001 - Operation & Service

July 6, 2001

Page 15 of 60

TOTAL COUNTER RESET

This software contains a special access code that enables the service person to reset all
the counters to zero, including the "

VEND TOTAL

" counter. This operation should be

performed before a unit is re-installed in the field.


1. To perform a "

TOTAL COUNTER RESET

",

a) Switch the power to the coffee maker "

OFF

" (switch is at the rear of the

unit).

b) Press the "

SET

-

UP

" mode button on the inside door panel and keep it

depressed.

c) With "

SET

-

UP

" mode button pressed, switch power to coffee maker "

ON

".

d) The following message will now appear on the display,


e) Enter the "

TOTAL COUNTER RESET

" access code (described below).





"TOTAL COUNTER RESET" ACCESS CODE


The following is the factory preset "

TOTAL COUNTER RESET

" access code - press the

following in the sequence outlined below;

1 COFFEE
2 MILD

STRENGTH

3 LARGE

CUP

4 MEDIUM

CUP

5 SMALL

CUP


Once the access code has been entered, a counter will appear on the top left of the
display, and will quickly increment from 0 to 255. Once this is complete, press

START

” for the brewer to cycle once to re-establish its home position.







ENTER ACCESS

CODE:

!

Note:

When the reset is
complete, the unit
will automatically
exit to the
“standby” mode,
and the internal
light will remain

ON

” temporarily.