Magnum Energy ME-ARC Remote User Manual

Page 3

background image

Magnum Energy, Inc.

PN: 64-0030-040 Rev C

Page 3 of 4

8:00P

10:00A

OFF

8:00A

1.0 Hrs

04I Gen Warm-up Time

≥Level 1

04J Gen Cooldown Time

≥Level 1

12:00A

05A Charge Eff

≥Level 1 [7]

05B AmpHour Size

≥Level 1 [7]

≥Level 1

200 ADC

13.8*

Time

2.0 Hrs

Max CC/CV Time= (OFF, 0.1-25.5 Hrs)

12.0 Hrs

ReCharge Volts = (9.0-16.0)*

12.0*

20 ADC

Max CC/CV Time= (OFF, 0.1-25.5 Hrs)

12.0 Hrs

ReCharge Volts = (9.0-16.0)*

12.0*

14.4*

13.2*

15.6*

4.0 Hrs

20 ADC

100%

06C Max Charge Rate

≥Level 1

06D Max Charge Time

≥Level 1

06H PowerSave PT Display

≥Level 1

Inv BTS:

≥Level 1

Inv Tfmer:

≥Level 1

Inv FETs:

≥Level 1

AGS Sensor:

≥Level 1

ACLD Temp

≥Level 1

PT BTS

≥Level 1

PT FETs

≥Level 1

PT Inductor

≥Level 1

Inverter:

≥Level 1

Remote:

≥Level 1

AGS:

≥Level 1

BMK:

≥Level 1

Router:

≥Level 1

ACLD:

≥Level 1

PT:

≥Level 1
≥Level 1

04A Inv Faults

≥Level 1

04A AGS Faults

≥Level 1

04C PT Faults [F]

≥Level 1

04D Clear Faults

≥Level 1

05 SETUP PIN

SETUP PIN =

≥Level 1
≥Level 1
≥Level 1

08

Load Defaults Defaults in x.xs

≥Level 1

06 PT Setup [F]

SETUP

04 AGS Setup

≥Level 1

≥Level 1

≥Level 1

≥Level 1

Alarm OFF Volts = 8.0-16.6*

14.0*

Alarm OFF = 0-127 Sec, 1-127 Min

10 Sec

Alarm ON Delay = 0-127 Sec, 1-127 Min

10 Sec

OFF, 0.1-25.5 Hrs

12.0 Hrs

OFF, 1-60 Min

15 Min

06E Bulk Start

Daily/SunUp = YES, NO

YES

SOC = 50%-100% [6]

80%

06G PT Alarm

Alarm ON Volts = 8.0-16.6*

10.0*

12.0*

Custom

EQ Done Time (0.1-25.5 Hrs)

≥Level 1

SOC= 50-100% [6]

0-100%

Absorb Volts (12.0-16.6)*

06B Absorb Done

2.0 Hrs

100%

06F PT Aux Relay

Relay Engage Volts = 8.0-16.6*

10.0*

Relay Engage Delay = 0-127 Sec, 1-127 Min

10 Sec

Relay Disengage Volts = 8.0-16.6*

Volts = OFF, 9.0-16.0*

Float Volts (12.0-16.6)*

Time= 0.1-25.5 Hrs

Amps= 0-150 ADC

06A Battery Type

≥Level 1

CV Chg Done= Amps (0-250 ADC)

CV Chg Done= Hold CV Chg VDC

Read Only

0-127 Sec, 1-127 Min

60 Sec

100% SOC Run Hour/Min/AM-PM= 12:00A-11:45P

Read only display
Read only display
Read only display

04K Gen 100% SOC Start Days
[F]

≥Level 1 [7]

Start Quiet Time= 12:00A-11:45P

Read only display

Flooded:

14.0*

10 Sec

Read Only

Read only display
Read only display

Read Only
Read Only
Read Only
Read Only

Read only display
Read only display
Read only display

Read Only

Read Only
Read Only

Read Only
Read Only

Read Only
Read Only
Read Only
Read Only

Read Only

TECH

Read only display
Read only display
Read only display
Read only display

Read only display

01 Temperatures

02 Versions

03 Inv Model:

04 Fault History

Read Only
Read Only
Read Only

Read only display
Read only display

Gel,

Flooded,

AGM,

AGM2

CC/CV [F]

Display Resettable

Resettable

Unlock SETUP, Lock SETUP, Change PIN

Unlocked

06 Ext Control

Read only display

Read Only

07 Show All Menus [F]

YES, NO

NO**

Read only display

Read Only

Max Chg Amps = (OFF, 20A-990 ADC)

CV Charge Volts = (12.0-16.6)*

Auto

400 AH

≥Level 1

≥Level 1

60 Sec

OFF

OFF

OFF

Read only display

Run Time= 0.1-25.5 Hrs

Read only display

CV Chg Done= (Time, Amps, Hold VDC)

CV Chg Done= Time (0.1-25.5 Hrs)

0-127 Sec, 1-127 Min

OFF, 1-255

Auto, 50-97%
200-2500 AH

Quiet Time Topoff= OFF, 30-120Min

OFF, ON

Stop Quiet Time= 12:00A-11:45P

Days= OFF, 1-255 days
Run Hour/Min/AM-PM= 12:00A-11:45P

Press SELECT (x5 Secs) for default settings

Relay Disengage Delay = 0-127 Sec, 1-127 Min

05 BMK Setup

04H Gen Exercise

04G Quiet Time