Changing power supply fuse (linear power supply), More assistance – Logitek Electronic Systems AE-32 Audio Engine User Manual
Page 29

Maintenance
Logitek Audio Engine Reference Manual
27
Changing Power Supply Fuse (Linear Power Supply)
To change the fuse in a Linear Power Supply, follow these steps:
1.
Press down on the top edge of the fuse cap, and then pull it out. This will release the fuse
capsule.
2.
Remove the fuse from the capsule.
3.
Replace with a suitable fuse. (GMA type with a rating of 1.3 amps slow-blow for 110V or
0.63 amps slow-blow for 220V)
4.
Re-insert the fuse capsule by pushing it back into the Power Supply until it snaps into place.
More Assistance
If you would like more assistance with maintenance and service, please contact Logitek Electronic
Systems
or your reseller.
You can also post questions and review other users’ experiences at the Logitek support forum. See
www.logitekaudio.com and follow the links to Tech Support Forum.