Operation

Logitek Audio Engine Reference Manual

24

Full Reset

A Full Reset is executed by pressing and holding down the red ACCEPT/FULL button on the Power

Supply

and the black Reset button on the AE-C2 or AE-C6 Communications Controller card.

Release the black Reset button first and when the bottom line of the LCD screen displays the
message

FULL, then release the red ACCEPT/FULL button.


If two power supplies are in place, either ACCEPT/FULL button may be used.


A Full Reset copies the default startup state of the last configuration saved, erasing any routing, level

or on/off information currently held in memory. The Audio Engine LCD display bottom line will
show the message

Full. This function is required to activate the routing portion of a new

configuration file or to clear the current state memory if it becomes corrupted.

AE-C6 cards with firmware of v3.67 or above will automatically perform a
Quick Reset after 5 seconds. This is to assist the system cards to boot up,
particularly from a cold state.

TIP:

As a

Full Reset

will reset to default routes, audio interruption will likely result.

No Config Reset

A No Config Reset is executed by pressing and holding down the green or black (depending on
Power Supply type) ESCAPE/IDLE button on the Power Supply and the black Reset button on the
AE-C2 or AE-C6 Communications Controller. Release the black Reset button first and when the
bottom line of the LCD screen displays the message

Config Not Loaded, then release the green

or black ESCAPE/IDLE button.


If two supplies are in place, either ESCAPE/IDLE button may be used.

AE-C6 Cards with firmware of v3.67 to v3.74 will automatically perform
another Quick Reset after 5 seconds. When performing a No Config Reset,

you must continue to hold the ESCAPE/IDLE button until after the 2

nd

reset.

This was resolved from firmware v3.75.

With this reset the Audio Engine does not load a configuration file or set any switch, route, mode,
or gain positions. The sample rate is set to 48 KHz. This procedure may be necessary if a
configuration becomes corrupted in some way or if a card failure has occurred. If a configuration

will not load, using this function will, in most cases, allow the configuration to load. The Audio
Engine

LCD display bottom line will show the message

Config Not Loaded.