Elation Professional Professional Model Impression Mounting Light User Manual
Page 8

 
 
©Elation Professional® 8 impression™
1. Head / LED Lens Assembly – The head assembly consist of the main output
lenses, and LED cluster module. A high-velocity variable speed fan is mounted in 
the head to aid in the cooling process. The fan is designed to vary the velocity at 
different operating temperatures. When the fixture reaches a predetermined 
internal operating temperature the fan functions at high speeds. The higher speeds 
provide better cooling associated with higher operating temperatures during long 
use. When the fixture is operating at a lower temperature the fans operate at low 
speed. Be sure to keep all vents clean, blocked cooling vents can shorten lamp life 
and reduce the fixtures reliability. For more information on the fan functions see 
page 23, section 3.9.7. 
 
2. Arm / Cooling Fan – A high-velocity variable speed fan is mounted in the head to
aid in the cooling process. The fan is designed to vary the velocity at different 
operating temperatures. When the fixture reaches a predetermined internal 
operating temperature the fan functions at high speeds. The higher speeds provide 
better cooling associated with higher operating temperatures during long use. 
When the fixture is operating at a lower temperature the fans operate at low speed. 
Be sure to keep all vents clean, blocked cooling vents can shorten lamp life and 
reduce the fixtures reliability. For more information on the fan functions see page 
23, section 3.9.7. 
 
3. 4-Segment Menu Display – This display details menu functions. 
a) Mode Select Button – This button is used to access the fixture’s main
system menu and on-board programming functions.
b) Enter Select Button – This button is used to select and confirm a menu
function when working in the fixture’s operating system.
c) Down Select Button – This button is used to scroll backwards when
navigating through the system menu.
d) Up Select Button - This button is used to scroll forward when navigating
through the system menu.
4. Base - This fixture uses an integrated Camlock system for various mounting
options built in to the base. The Camlock clamp system allows a quick and efficient 
means to secure the unit. For proper installation see “Mounting and Installation” on 
page 12. 