Chapter 2, Hardware setup, Cpu and the heat sink installation – Lanner FW-8759 User Manual
Page 14
8
Hardware Setup
Chapter 2
Network Application Platforms
Note:
The CPU heat sink can only be installed in only
1.
one orientation as shown in the picture.
To protect the CPU socket pins, retain the CPU
2.
cap when the CPU is not installed.
CPU and the Heat Sink Installation
The FW-7585 sever system is powered by the MB-7585
sever board, which comes with one ZIF type LGA1150 CPU
socket.
Follow the procedure bellow for installing a CPU
Press the socket lever and release it from the retention
1.
tab.
Lift the socket lever and then the plate.
2.
Remove the CPU socket cap.
3.
Align the notches in the CPU base and the tabs on
4.
the socket. The CPU should fit perfectly into the
socket. Note that the CPU fits in the socket in only one
direction.
Close the CPU cover plate by lightly pressing down on
5.
the CPU cover plate while closing the socket lever.
Peel off the sticker on the CPU to expose the thermal
6.
compound.
Align the heatsink’s four mounting screws with the
7.
mounting holes in the chassis. Carefully place the
heatsink on the CPU. Tighten each heatsink screw
a little at a time to ensure that the CPU stays level.
Tighten each set of diagonally opposed screws at a
time.
2
3
1
5
4
6
7