12 technical data, Electrical data mini-argus, Electrical data mini-argus fr – KACO Powador Mini-Argus User Manual
Page 13
Mounting
Mini-Argus Operating Manual_EN
Page 13
Authorised electrician
5.12 Technical Data
Electrical data
Mini-Argus
U
OC
max.
1000 V
I
MPP
max.
34 A
inputs
5
String input terminal
Negative pole: 5 x spring-loaded terminals up to 10 mm
2
Positive pole: 5 x screw terminals up to 16 mm
2
Load disconnection point
integrated, with external actuator
String fuse
12 A in positive potential, string fuse 10 x 38
the fuses may be required depending on the module types
Overvoltage protection
Class II / "C" (medium protection)
Output terminals
Long-range terminal 6-35 mm
2
Grounding: screw terminal 16 mm
2
Protection rating
IP65
Protection class
II
Housing
Polycarbonate smoke grey, transparent screw-mounted cover,
Pressure compensation element
Cable insertion
DIN screws
H x W x D
300 x 300 x 130 mm
Electrical data
Mini-Argus FR
U
OC
max.
1000 V
I
MPP
max.
34 A
inputs
5
String input terminal
Negative pole: DC solar sockets
Positive pole: DC solar plugs
Load disconnection point
integrated, with external actuator
String fuse
12 A in positive and negative potential, string fuse 10 x 38
the fuses may be required depending on the module types
Overvoltage protection
Class II / "C" (medium protection)
Output terminals
Long-range terminal 6-35 mm
2
Grounding: screw terminal 16 mm
2
Protection rating
IP65
Protection class
II
Housing
Polycarbonate smoke grey, transparent screw-mounted cover,
Pressure compensation element
Cable insertion
DC plugs/sockets
H x W x D
300 x 300 x 130 mm