5.12 Technical Data

Electrical data

Mini-Argus

U

OC

max.

1000 V

I

MPP

max.

34 A

inputs

5

String input terminal

Negative pole: 5 x spring-loaded terminals up to 10 mm

2

Positive pole: 5 x screw terminals up to 16 mm

2

Load disconnection point

integrated, with external actuator

String fuse

12 A in positive potential, string fuse 10 x 38

the fuses may be required depending on the module types

Overvoltage protection

Class II / "C" (medium protection)

Output terminals

Long-range terminal 6-35 mm

2

Grounding: screw terminal 16 mm

2

Protection rating

IP65

Protection class

II

Housing

Polycarbonate smoke grey, transparent screw-mounted cover,

Pressure compensation element

Cable insertion

DIN screws

H x W x D

300 x 300 x 130 mm

Electrical data

Mini-Argus FR

U

OC

max.

1000 V

I

MPP

max.

34 A

inputs

5

String input terminal

Negative pole: DC solar sockets

Positive pole: DC solar plugs

Load disconnection point

integrated, with external actuator

String fuse

12 A in positive and negative potential, string fuse 10 x 38

the fuses may be required depending on the module types

Overvoltage protection

Class II / "C" (medium protection)

Output terminals

Long-range terminal 6-35 mm

2

Grounding: screw terminal 16 mm

2

Protection rating

IP65

Protection class

II

Housing

Polycarbonate smoke grey, transparent screw-mounted cover,

Pressure compensation element

Cable insertion

DC plugs/sockets

H x W x D

300 x 300 x 130 mm