Jordan Valve Mark 508 Series – Tank Blanketing Valve User Manual
Page 13
TABLE 6 TANK BLANKETING VALVE CAPACITIES 3/4” MARK 608BP WITH 5/16” ORIFICE
Range
Setpoint
Inlet Pressure
330Nitrogen @ 0.97sg
Deviation from Setpoint (in/water)
+/- 0.5
+/- 1.0
+/- 2.0
2 - 5.5" w.c.
4" w.c.
5
318
849
919
20
563
1408
2065
40
825
3417
3535
60
2341
4957
4957
4 - 10" w.c.
7" w.c.
5
247
495
849
20
469
1126
1877
40
707
2003
3535
60
1239
3305
4957
80
1860
6046
6511
5 - 30" w.c.
20" w.c.
5
71
283
212
20
188
563
469
40
118
943
825
60
344
1377
1102
80
310
1860
1473
100
299
2218
1706
125
188
2824
1789
150
220
3301
2091
0.5 - 1.75 psi
1 psi
5
159
283
636
20
282
563
1783
40
471
943
2592
60
551
1377
3442
80
775
1860
6201
100
1365
2218
7166
125
1318
2824
8850
150
1541
3301
10456
1 - 3.5 psi
3 psi
5
354
707
919
20
845
1877
2158
40
1296
2946
3535
60
2065
4819
5095
80
2636
6046
6511
100
3242
7166
8019
125
3766
8850
9415
150
4458
10456
11117
-10-
This manual is related to the following products: