beautypg.com

Jordan Valve Mark 508 Series – Tank Blanketing Valve User Manual

Page 13

background image

TABLE 6 TANK BLANKETING VALVE CAPACITIES 3/4” MARK 608BP WITH 5/16” ORIFICE

Range

Setpoint

Inlet Pressure

330Nitrogen @ 0.97sg

Deviation from Setpoint (in/water)

+/- 0.5

+/- 1.0

+/- 2.0

2 - 5.5" w.c.

4" w.c.

5

318

849

919

20

563

1408

2065

40

825

3417

3535

60

2341

4957

4957

4 - 10" w.c.

7" w.c.

5

247

495

849

20

469

1126

1877

40

707

2003

3535

60

1239

3305

4957

80

1860

6046

6511

5 - 30" w.c.

20" w.c.

5

71

283

212

20

188

563

469

40

118

943

825

60

344

1377

1102

80

310

1860

1473

100

299

2218

1706

125

188

2824

1789

150

220

3301

2091

0.5 - 1.75 psi

1 psi

5

159

283

636

20

282

563

1783

40

471

943

2592

60

551

1377

3442

80

775

1860

6201

100

1365

2218

7166

125

1318

2824

8850

150

1541

3301

10456

1 - 3.5 psi

3 psi

5

354

707

919

20

845

1877

2158

40

1296

2946

3535

60

2065

4819

5095

80

2636

6046

6511

100

3242

7166

8019

125

3766

8850

9415

150

4458

10456

11117

-10-