Please read these instructions carefully!

Your Jordan Valve product will provide you with

long, trouble-free service if it is correctly installed

and maintained. Spending a few minutes now read-

ing these instructions can save hours of trouble and

downtime later.

When making repairs, use only genuine Jordan Valve

parts, available for immediate shipment from the fac-

tory.

3170 Wasson Road • Cincinnati, OH 45209
Phone 513.533.5600 • Fax 513.871.0105 (f)
[email protected] • www.jordanvalve.com

I & M Mark 695 Series

Installation & Maintenance Instructions for the

Mark 695 Internally Piloted Tank Blanketing Valve

Warning: Jordan Valve Pressure Regulators must only be used, installed and repaired in accordance with these
Installation & Maintenance Instructions. Observe all applicable public and company codes and regulations. In the
event of leakage or other malfunction, call a qualified service person; continued operation may cause system failure
or a general hazard. Before servicing any valve, disconnect, shut off, or bypass all pressurized fluid. Before disas-
sembling a valve, be sure to release all spring tension.

-1-

Ideal Installation

1. To protect the valve from grit, scale, thread

chipsand other foreign matter, ALL pipelines

and pipingcomponents should be blown out and

thoroughly cleaned before the installation process

begins.

2. Shutoff valves, pressure gauges and by-pass piping

are optional, and if installed should be in accordance

with all applicable codes, standards, and practices.

They are recommended to provide easier adjustment,

operation, and testing.

3. The flow arrow on the valve body must be pointed

in the direction of flow. Ideally, the valve should be

installed in the highest horizontal line of piping.

4. Install the relief valve on the tank. Set above the

control point of the valve but below the maximum

safety limit for the tank.

5. It is strongly recommended that the installer read

and be thoroughly familiar with API 2000, Standard

Information for Tank Blanketing Regulator Selection

before installing and attempting to operate this

product.

Control Line

A control line must be installed as follows:

1. Connect one end of a 3/8” tube to the fitting on the

bottom of the main valve actuator.

2. Connect the other end to an appropriate fitting on

the tank.

3. DO NOT locate the control line tap in any location

where turbulence or abnormal velocities may occur.

4. The control line should be sloped away from the

valve.

5. Install a pressure gauge to measure pressure in the

tank itself, not in the outlet piping or the control line

to aid in setting the valve.

Control Line Piping Recomendation

Keep the regulator as close to the tank as possible

and as high as possible.

Minimize the length of the downstream pipe coming

from the valve.