CLEARANCES

Minimum Wall and Ceiling Clearances

30”

(762mm)

4”

(101mm)

Figure 4

This fireplace can be installed with zero (0") clearance to

combustible material

When facing the front of the appliance the minimum clearances

to combustible construction (material) are the following:

1. Clearances from the right side or left side of the fireplace

opening to any combustible wall or material should not be

less than 4 inches.

2. Clearances from the top of the fireplace opening to the ceiling

should not be less than 30 inches.

Mantel Clearances for Built-in Installation

Figure 5

COMBUSTIBLE MATERIAL

Do not attach combustible material to the mantel of your fireplace.

This is a fire hazard.

Figure 6

No greeting cards, stockings or ornamentation of any type should

be placed on or attached to the fireplace. This is a heating appliance.

The flow of heat can ignite combustibles.

Figure 7