FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by

hand. When lighting the pilot, follow these instructions

exactly.

B. BEFORE LIGHTING smell all around the appliance

area for gas. Be sure to smell next to the floor because some

gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch;

do not use any phone in your building.

• Immediately call your gas supplier from a neighbor's

phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control

knob. Never use tools. If the knob will not push in or

turn by hand, don't try to repair it; call a qualified

service technician. Force or attempted repair may

result in a fire or explosion.

D. Do not use this appliance if any part has been under

water. Immediately call a qualified service technician

to inspect the appliance and to replace any part of

the control system and any gas control which has

been under water.

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

1. Turn control knob clockwise

to OFF position to

completely shut off the heater.

2. If applicable: Turn ON/OFF switch to OFF position and/or

set thermostat (if present) to lowest setting. If applicable:

Turn off all electric power to the heater.

1. STOP! Read the safety information label.

2. Make sure the manual shutoff valve is fully open.

3. This gas log set is equipped with an ignition device (piezo)

which lights the pilot. If piezo ignitor does not light the pilot,

refer to Step 7.

4. Turn gas control knob clockwise

to the “OFF”

position, set the thermostat to the lowest setting and turn

ON/OFF switch to OFF position.

5. Wait ten (10) minutes to clear out any gas. Then smell for

gas, including near the floor. If you smell gas STOP! Follow

“B” in the safety information label. If you do not smell gas,

go to the next step.

6. From OFF position, turn the gas control knob counterclock-

wise

to “Pilot” position. Push in and hold control

knob for 5 seconds.

7. With the control knob pushed in, repeatedly push the piezo

ignitor button until pilot is lit (or use a match to light pi-

lot).

8. Continue pushing the control knob in for a further 60 seconds

to prevent the flame detector from shutting off the gas while

the probe is warming up. Release the control knob.

9. Turn gas control knob counterclockwise

to the

“ON” position.

10. After the pilot has been lit for one minute, the burner can

be turned on. Turn the ON/OFF switch to “ON” position

or adjust thermostat to desired setting.

11. If the gas logs will not operate, follow the instructions “To

Turn Off Gas To Appliance” and call your service techni-

cian or gas supplier.

Wait 30 seconds before readjusting the heater when the control

knob has been turned down to a lower setting.