beautypg.com

Placement of glowing embers (rock wool), Operation instructions/flame appearance – Empire Comfort Systems VFHS-20/10T-4 User Manual

Page 12

background image

Page 12

16717-2-0605

PLACEMENT OF GLOWING EMBERS (ROCK WOOL)

Provided with the log set is a small bag of glowing embers (rock

wool) to be placed between logs on the flat metal surface of the

burner.
Placement of the embers (rock wool) is very individual and light

coverage of the areas indicated will provide your best effects. We

recommend separation of the rock wool by hand and make your

coverage as light and fluffy as possible.
Place just enough embers (rock wool) on the burner to obtain the

glow and a gold yellow flame.
Do not place rock wool over large ports in rear portion of

burner.

OPERATION INSTRUCTIONS/FLAME APPEARANCE

Flames from the pilot (rear right back side of the pan burner) as

well as the main flame should be visually checked as the log set

is installed.
In normal operation at full rate after 10 to 15 minutes, the flame

appearance should be sets of yellow flames.
NOTE: all flames will be random by design, flame height will

go up and down.
Glowing embers (rock wool) can cover the pan burner in between

the front and middle logs, but very little is necessary to cover this

area. Excess ember material causes the yellow flame to become

orange and stringy. Apply just enough to obtain slow glow and a

gold, yellow flame.
Avoid any drafts that alter burner flame patterns. Do not allow fans

to blow directly into fireplace. Do not place a blower inside the

burner area of the firebox. Ceiling fans may create drafts that alter

flame patterns. Sooting and improper burning will result.

During manufacturing, fabricating and shipping, various

components of this appliance are treated with certain oils, films or

bonding agents. These chemicals are not harmful, but may produce

annoying smoke and smells as they are burned off during the initial

operation of the appliance, possibly causing headaches or eye or

lung irritation. This is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner

at the highest setting. Provide maximum ventilation by opening

windows or doors to allow odors to dissipate. Any odors remaining

after this initial break-in will be slight and will disappear with

continued use.
This appliance must not be used with glass doors in the closed

position. This can lead to pilot outages and severe sooting outside

the fireplace.

A thin layer of rock wool should be placed under open space

between the right and left middle logs.
Rock wool should not be placed in the area of the pilot

assembly.
Replacement of loose material (glowing embers) must be

purchased from Empire Comfort Systems, Inc. Application of

excess loose material (glowing embers) may adversely affect

performance of the heater. WARNING: All previously applied

loose material must be removed prior to reapplication.
Refer to Parts List, Page 20 to order loose material (rock wool).