2 symbol list, 1 symbol list – Yaskawa MP900 Series Machine Controller New Ladder Editor User Manual
Page 151

5 SYMBOL DATABASE
5.2.1 Symbol List
5-4
5.2 SYMBOL LIST
The content of the registered symbols is referred and defined in the symbol list.
5.2.1 Symbol List
Double-click the All list on the Symbol List folder in the Data Tree Window and the regis-
tered symbol list is displayed.
1. Number of Registered Symbol
The number of the registered symbol is displayed.
2. Symbol
The symbol of the instruction is displayed and can be input. The length of the symbol is
up to the normal-width 64 characters.
3. Kind
The kind of register is displayed and can be selected.
4. Data Type
The data type of register is displayed and can be selected.
5. Register
The register address of the instruction is displayed and can be input.
• Global
: M register
• Input
: I register
• System
: S register
• Output
: O register
• Const
: C register
• Local
: D register
• LocalConst
: # register
• Bit
: Bit type
• Long
: Double Integer-type
• Word
: Integer type
• Float
: Real type
• Address
: Address type
1
10
2
3
4
5
6
7
8
9