18 Ethernet Connector Details

40

YASKAWA America, Inc. MP3200iec Hardware Manual YAI-SIA-IEC-5

‹

Ethernet Connection Examples

The following are examples of Ethernet network connections via 10Base-Tx cable:

„

Connection Example 1 (When using a hub or switch)

„

Specification

„

Connection Example 2

Item

When Connecting to a Repeater HUB

When Connecting to a Switching HUB

Cable Length between Node-HUB

100m or less

100 m or less

Cable Length between HUBs

100m or less

100 m or less

Number of HUBs between Nodes

Up to four

Unlimited

Hub

or Switch

MP3200iec

Hub

or Switch

10Base-T

(Straight cable)

Station

Station

Station

Up to 100m

Up to 100m

Up to 100m

Up to 100m

Up to 100m

Station

Up to 100m

When connecting to a HUB without using the
auto-negotiation function, set the HUB side to
half-duplex mode.

10 Base-T (crossover cable, up to 100m)