8 Base Unit Installation and Operating Conditions

16

YASKAWA America, Inc. MP3200iec Hardware Manual YAI-SIA-IEC-5

‹

Mechanical Operating Conditions

‹

Electrical Operating Conditions

Item

Specification

Vibration Resistance

Conforms to JIS B 3502.
10 Hz

≤ f < 57 Hz with vibration amplitude of 0.075 mm

57 Hz

≤ f ≤ 150 Hz with fixed acceleration of 9.8 m/s

2

10 sweeps each in X, Y, Z directions (sweep: 1 octave/min)

Shock Resistance

Conforms to JIS B 3502.
Peak acceleration of 147 m/s

2

twice for 11 ms each in the X, Y, and Z directions

Item

Specification

Noise Resistance

Conforms to EN 61000-6-2 and EN 55011 (Group 1 Class A).
Power supply noise (FT noise): 2 kV min. for 1 minute

Radiation noise (FT noise): 1 kV min., for 1 minute

Ground noise (impulse noise): ±1 kV min., for 10 minutes

Electrostatic noise (conducted): ±4 kV min., 10 times

Ground Information

Ground to 100

ȍ

max.

Fan

CPU Unit’s internal resistance to

air flow: 6

×10

6

(N

⋅s

2

/m

8

)

40 mm min.

30 mm min.

Average airflow:

0.03 m

3

/min

30 mm min.

40 mm min.