11 EMC Installation Conditions

42

Three-phase 400 V

SGDV-DE1A ( = 210, 260, 280, 370) + SGDV-OCC02A

* 1. Products that have received CE marking are recommended for the 24 VDC power supply.
* 2. Install the following noise filter on the power line between the single-phase 200 V power

supply and the 24 VDC power supply.
Model number: FN2070-6/07 (SCHAFFNER).

* 3. For more information on this filter, refer to Sigma-5 Product Catalog

(YEA-KAEPS80000042).

Symbol

Cable Name

Specification

I/O signal cable

Shield cable

Safety signal cable

Shield cable

Motor main circuit cable

Shield cable

Encoder cable

Shield cable

Control power cable

Shield cable

Main circuit cable

Shield cable

Regenerative resistor unit cable

Non-shield cable

Ethernet communication cable

Shield cable

U, V, W

L1, L2, L3

24 V, 0 V

CN2

CN1

PE

PE

1

2

3

6

5

CN8

B1, B2

7

4

Power supply:

Single-phase

200 VAC

Power supply:

Three-phase

400 VAC

Clamp

Surge

absorber

Surge

absorber

Clamp

Noise

filter*

2

Noise

filter*

3

Brake Power

Supply

Shield box

Control

power

supply

24 VDC*

1

SERVOPACK

Encoder

Servomotor

Brake

Clamp

Clamp

Clamp

General I/O

Safety unit

Clamp

Clamp

Regenerative

resistor unit

PC

Controller

8

CN1

1 A/B

SigmaLogic

Core

One turn

General I/O

1

CN13

SigmaLogic

Core

Clamp

One turn