Three-phase 400 v, 11 emc installation conditions – Yaskawa SigmaLogic User Manual
Page 44

11 EMC Installation Conditions
42
Three-phase 400 V
SGDV-DE1A ( = 210, 260, 280, 370) + SGDV-OCC02A
* 1. Products that have received CE marking are recommended for the 24 VDC power supply.
* 2. Install the following noise filter on the power line between the single-phase 200 V power
supply and the 24 VDC power supply.
Model number: FN2070-6/07 (SCHAFFNER).
* 3. For more information on this filter, refer to Sigma-5 Product Catalog
(YEA-KAEPS80000042).
Symbol
Cable Name
Specification
I/O signal cable
Shield cable
Safety signal cable
Shield cable
Motor main circuit cable
Shield cable
Encoder cable
Shield cable
Control power cable
Shield cable
Main circuit cable
Shield cable
Regenerative resistor unit cable
Non-shield cable
Ethernet communication cable
Shield cable
U, V, W
L1, L2, L3
24 V, 0 V
CN2
CN1
PE
PE
1
2
3
6
5
CN8
B1, B2
7
4
Power supply:
Single-phase
200 VAC
Power supply:
Three-phase
400 VAC
Clamp
Surge
absorber
Surge
absorber
Clamp
Noise
filter*
2
Noise
filter*
3
Brake Power
Supply
Shield box
Control
power
supply
24 VDC*
1
SERVOPACK
Encoder
Servomotor
Brake
Clamp
Clamp
Clamp
General I/O
Safety unit
Clamp
Clamp
Regenerative
resistor unit
PC
Controller
8
CN1
1 A/B
SigmaLogic
Core
One turn
General I/O
1
CN13
SigmaLogic
Core
Clamp
One turn