4.4 Digital I/O

4.4.2 Outputs

17

4.4.2

Outputs

• 8 general purpose
• Optically isolated
• 24 V @ 50 mA
• Current source or sink (connection to both emitter and collector are

provided)

Connection Examples of Output Circuits

• Relay Circuit Example

• Line Receiver Circuit Example

0 V

Relay

5 to 24 VDC

SERVOPACK

SERVOPACK

5 to 12 VDC