11 EMC Installation Conditions

43

Three-phase 400 V

SGDV-

DE1A ( = 1R9, 3R5, 5R4, 8R4, 120, 170)

+ SGDV-OCC02A

* 1.

Products that have received CE marking are recommended for the 24 VDC power supply.

* 2. Install the following noise filter on the power line between the single-phase 200 V power

supply and the 24 VDC power supply.

Model number: FN2070-6/07 (SCHAFFNER).

* 3. For more information on this filter, refer to Sigma-5 Product Catalog

(YEA-KAEPS80000042).

Symbol

Cable Name

Specification

I/O signal cable

Shield cable

Safety signal cable

Shield cable

Motor main circuit cable

Shield cable

Encoder cable

Shield cable

Control power cable

Shield cable

Main circuit cable

Shield cable

Ethernet communication cable

Shield cable

U, V, W

L1, L2, L3

24 V, 0 V

CN2

CN1

PE

PE

1

2

3

6

5

CN8

4

SERVOPACK

Brake Power

Supply

General I/O

Safety unit

Encoder

Servomotor

Brake

Shield box

Clamp

Clamp

Core

Core

Clamp

Core

Core

Clamp

Noise
filter*3

Core

Core

Surge

absorber

Surge

absorber

Core

Noise
filter*2

Control

power

supply

24 VDC*1

Clamp

Clamp

Clamp

One turn

One turn

Two turn

Two turn

One turn

Power supply:

Single-phase

200 VAC

Power supply:

Three-phase

400 VAC

PC

Controller

7

CN1

1 A/B

MP2600iec

Core

One turn

General I/O

1

CN13

MP2600iec

Core

Clamp

One turn