5 dip switches, 1 switch settings – Yaskawa MP2600iec User Manual
Page 23

5.1 Switch Settings
21
5 DIP
Switches
5.1 Switch Settings
S11
DHCP
EINIT
CNFG
INT
SUP
STOP
NO
Switch
Name
Setting
Operating Mode
Setting for
Normal
Operation
Details
1
STOP
ON
User program execution
inhibited
OFF
Inhibits user program execution
OFF
Normal operation
2
SUP
ON
Firmware programming
mode
OFF
Enables controller firmware programming.
(See Section 11)
OFF
Normal operation
3
INIT
ON
SRAM/clock initialization
and configuration bypass
mode
OFF
Set to ON to bypass the stored configuration
(e.g. in case of a configuration problem that
prevents controller startup) or to initialize the
SRAM contents and clock settings after
backup power has been lost (See Section
7.1).
OFF
Normal operation
4
CNFG
ON
Normal operation
ON
Always set to ON
OFF
Do not set (reserved for
future use)
5
E-INIT
ON
Force Ethernet address
setting for Port A to
192.168.1.1 and Port B
to 192.168.2.1
OFF
Enables use of the default Ethernet
addresses
OFF
Normal Operation
6
DHCP
ON
DHCP-configured IP
settings
OFF
Enables use of DHCP for IP setting
configuration
OFF
Manually-configured IP
settings
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)