Checking PG Pulses
Step 13 (for GPD 515/G5 models)
Test Equipment - Ungrounded oscilloscope with x10 probe.
Set scope to 5V/division and .01mSeconds, in order to observe the PG pulses.
3. Command the inverter to run in the forward direction with a reference of 60 Hz.
The “A” pulse (channel 1) should lead the “B” pulse (channel 2) by 90°. 
Compare the waveforms with the picture below. 
                    This manual is related to the following products:                                    
                                                                        See also other documents in the category Yaskawa Equipment:                                                            
                    - Tag Generator (30 pages)
 - MP3300iec (82 pages)
 - 1000 Hz High Frequency (18 pages)
 - 1000 Series (7 pages)
 - PS-A10LB (39 pages)
 - iQpump Micro User Manual (300 pages)
 - 1000 Series Drive Option - Digital Input (30 pages)
 - 1000 Series Drive Option - CANopen (39 pages)
 - 1000 Series Drive Option - Analog Monitor (27 pages)
 - 1000 Series Drive Option - CANopen Technical Manual (37 pages)
 - 1000 Series Drive Option - CC-Link (38 pages)
 - 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
 - 1000 Series Drive Option - DeviceNet (37 pages)
 - 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
 - 1000 Series Drive Option - MECHATROLINK-II (32 pages)
 - 1000 Series Drive Option - Digital Output (31 pages)
 - 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
 - 1000 Series Drive Option - Profibus-DP (35 pages)
 - AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
 - Z1000U HVAC MATRIX Drive Quick Start (378 pages)
 - 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
 - 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
 - CopyUnitManager (38 pages)
 - 1000 Series Option - JVOP-182 Remote LED (58 pages)
 - 1000 Series Option - PG-X3 Line Driver (31 pages)
 - SI-EN3 Technical Manual (68 pages)
 - JVOP-181 USB Copy Unit (2 pages)
 - JVOP-181 (22 pages)
 - SI-EN3 (54 pages)
 - MECHATROLINK-III (35 pages)
 - SI-ET3 (49 pages)
 - EtherNet/IP (50 pages)
 - SI-EM3 (51 pages)
 - 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
 - 1000-Series Option SI-EP3 PROFINET (56 pages)
 - PROFINET (62 pages)
 - AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
 - SI-EP3 PROFINET Technical Manual (53 pages)
 - A1000 Drive Option - BACnet MS/TP (48 pages)
 - 120 Series I/O Modules (308 pages)
 - A1000 12-Pulse (92 pages)
 - A1000 Drive Software Technical Manual (16 pages)
 - A1000 Quick Start (2 pages)
 - JUNMA Series AC SERVOMOTOR (1 page)
 - A1000 Option DI-101 120 Vac Digital Input Option (24 pages)
 