beautypg.com

Output current waveform – Yaskawa GPD 506/P5 Section Two User Manual

Page 22

background image

PP.P5G5.02Troubleshoot

Page 22

Rev. 06/11/2003

Output Current Waveform

Step 11
Test Equipment - Ungrounded oscilloscope with clamp on current probe.
Set scope to 10mV/division and 5mSeconds, in order to observe the output current waveform.

1. Using the clamp on current probe, clamp the probe to one of the output leads T1, T2, or T3.
2. Run the inverter up to 60 Hz, watching the waveform as it accelerates.
3. Compare the waveform with the waveform shown below. (Output will vary with load)
4. Stop the inverter.
5. Repeat steps 1 through 4 with the two remaining output leads.

This manual is related to the following products: