background image

PP.P5G5.02Troubleshoot

Page 14

Rev. 06/11/2003

Output Voltage Waveform

Step 7
Test Equipment - Ungrounded oscilloscope with X 100 probe
Set scope to 500V/division and 2mSeconds, in order to observe the output voltage waveform.
Before attempting to run the inverter, make a list of all the parameters that have been

changed from the factory settings. Initialize the drive and set it up to accept a run command

and frequency reference from the digital operator.

1. Using the oscilloscope, measure between T1 and T2.
2. Run the inverter up to 60 Hz, watching the waveform as it accelerates.
3. Compare the waveform with the waveform shown below.
4. Stop the inverter.
5. Repeat steps 1 through 4 measuring T1 to T3 and T2 to T3.