MP2300 Quick Reference Guide Rev1.5

Motion Program Work Registers for MSEE instruction

Bit

Name

Description

DB000000

Program Running

ON while running

DB000001

Program Paused

ON while paused

DB000002

program stopped with
program stop request

ON when stopped

DB000004

Program in Debug (Single
Block) Mode

ON during debug via ladder (registers)

DB000008

Program Alarm

ON when Motion Program Alarm has occurred

DB000009

Stopped at Break Point

DB00000B

Program Debugging Mode

ON during Windows (EWS) debug mode

DB00000D

Start request signal history

ON during request

DB00000E

Program Duplication Error

ON when another Motion Program in the same group has started while this
program is running

DB00000F

Program Number Limit Error ON when the number of steps in program exceeded maximum

DW00001

Bit

Name

Description

DB000010

Program Start Request

ON with rising edge. (if it CAN start it will, otherwise alarm)

DB000011

Program Pause Request

ON will pause motion blocks

DB000012

Program Stop Request

ON will stop all group motion, exit the Motion Program, and generate a motion
program alarm

DB000013

Program Debug Mode Select "Single block mode". ON will force debugging mode

DB000014

Program Debug Start

"Single Block Mode" start. ON (transition) debug block by block

DB000015

Program alarm Reset

ON will clear the program alarm (stop program before issuing alarm reset)

DB000016

Program Continuous
Operation Start Request

ON will cause program to ….

DB000018

Block Skip 1 Operation

ON will cause the program to skip an interpolated motion block if the SKP ss1
instruction was used instead of MVS

DB000019

Block Skip 2 Operation

ON will cause the program to skip an interpolated motion block if the SKP ss2
instruction was used instead of MVS

DB00001D

System Work Number
Setting

ON Sets system work register number with 4th word of MSEE work register

DB00001E

Interpolation Override Setting ON activates the interpolation override speed with the 3rd MSEE work register

DW00002

DW00003

3r

d Wor

k

R

egi

st

er

4t

h Wor

k

R

egi

st

er

INTERPOLATION OVERRIDE (Speed)

The speed set in this register [0.01% of FMX] will override the interpolation speed set in the motion program
(F & IFP commands) when bit E of the 2nd word of the MSEE work register is ON

SYSTEM WORK REGISTER

The system work register number in this register will be used when bit D of the 2nd word of the MSEE work
register is ON. Otherwise the system work register number will be automatically defined by the system and
may be different each time.

INPUT (Motion Program Control Signals)

DW00000

OUTPUT (Motion Program Status)

1st

Wor

k R

egi

st

er

2nd Wor

k R

egi

st

er

The "Data" field of the
MSEE instruction defines
the address for the output
and input registers of the
motion program.

Ex: DA00000 means that
DW00000 through
DW00003 will be used.

Page 11 of 14