Clearances locating fireplace – Empire Comfort Systems DVX36DP31 User Manual
Page 8
25613-0-0309
Page 8
Mantel Chart (Figure 3)
Figure 3
Clearances (Figure 4)
Clearance from top front edge of fireplace to ceiling is 36"
Clearance from side of fireplace to adjacent sidewall is 6".
36”
(914mm)
6” (152mm)
Figure 4
Figure 5
Note: Island (C) and Room Divider (F)
installation is possible as long as the
horizontal portion of the vent system
(H) does not exceed 20 feet with a
minimum vertical run of 8 feet. See
details in Venting Section.
When you install your Direct Vent
Fireplace in (F) Room divider or (A) Flat
on wall corner positions, a minimum of
6 inches clearance must be maintained
from the perpendicular wall and the
front edge of the appliance.
Figure 2
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
(A) CORNER
INSTALLATION
(E) ANGLED CORNER
INSTALLATION
(C) ISLAND
INSTALLATION
(B) CABINET
INSTALLATION
(F) ROOM DIVIDER
INSTALLATION
(D) FLUSH WALL
INSTALLATION
Clearance to Combustibles
Back
0" (0 mm)
Side
0" (0 mm)
Floor
0" (0 mm)
Top Stand-off
0" (0 mm)
Top Framing Edge
6" (152 mm)
GLASS FRONT
6”
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
2” x 4” HEADER
STAND OFF
6” (152mm) HEIGHT
ABOVE TOP OF
FIREPLACE
NAILING
FLANGES
TOP FRAMING
LEDGE
NON-COMBUSTIBLE
FIRST 6” (SEE
MAGNIFIED VIEW)
FINISHED WALL
(COMBUSTIBLE)
SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
CLEARANCES
LOCATING FIREPLACE
MANTEL
19”
18 3/4”
17”
16”
15”
14”
13”
12”
11”
10”
2 1/4”
1 1/2”
3/4”
8”
6”
4 1/2”
3 3/4”
3”
12” (305mm)
10” (254mm)
TOP EDGE OF FIREPLACE
COMBUSTIBLE TRIM AND
MANTELS ALLOWED IN
SHADED AREA