VENT CAP

9” (229mm) minimum
TO SIDE WALL

Figure 25

Figure 24

MINIMUM HOLE LOCATION DIMENSIONS FOR

THROUGH THE WALL HORIZONTAL INSTALLATIONS

WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE

Positioning the Fireplace

Determine the exact position of the appliance so the direct vent

termination will be centered (if possible) between two (2) studs. This

will avoid any extra framing. All vent kit pipes should be assembled

on the unit after the unit is moved into the final position.
Cutting the Hole (Figure 23)

After the fireplace has been positioned in its permanent location,

the hole through the exterior wall of the house can be cut. This hole

must be 12" (305 mm) high x 10" (254 mm) wide with its center

line determined by the amount of vertical rise and horizontal run of

the termination. See Figure 23. When locating the hole it must be

noted that the bottom of the cap must be 12" (305 mm) above the

ground level, and top of the cap must be no less than 18" (457 mm)

below a combustible projection, and no closer than 9" (229 mm) to

any wall running parallel to vent termination. See Figure 24.

FIREPLACE

SERIES

HARD ELBOW DIMENSIONS

"A"

"B"

"C"

DVX36FP

43-1/2"

(1105 mm)

5"

(127 mm)

7"

(178 mm)

DVX42FP

43-1/2"

(1105 mm)

5"

(127 mm)

7"

(178 mm)

FIREPLACE

SERIES

FLEX PIPE 90 DEGREE BEND

"A"

"B"

"C"

DVX36FP

46"

(1143 mm)

5"

(127 mm)

7"

(178 mm)

DVX42FP

46"

(1143 mm)

5"

(127 mm)

7"

(178 mm)

Figure 23

MAXIMUM HORIZONTAL
RUN WITH NO VERTICAL
RISE AND 90° ELBOW

3’

(914mm)

MAXIMUM HORIZONTAL
RUN WITH MINIMUM
VERTICAL RISE AND
90° ELBOW

20’ (6.1m)

PIPE STRAPS
EVERY 2’ (61cm)

8’ (244cm)
TO BOTTOM
OF UNIT

SEE CHART FOR

PERMISSIBLE

“H” AND “V”

DIMENSIONS

A

CENTER OF ELBOW

STRAIGHT OUT

(MINIMUM)

10”

(254mm)

C

B

V

C

B

H

12”

(305mm)