Venting fireplace - top (continued) – Empire Comfort Systems DVX36DP31 User Manual

Page 16

background image

25613-0-0309

Page 16

Figure 21

Examples of possible venting systems using two (2) 90° elbows.

V is listed as minimum vertical dimensions and H1 + H2 is listed

as total of maximum horizontal dimensions. The maximum vertical

and horizontal distances for two (2) 90° elbows as shown in Figure

22 is 22 feet.
Attention: Refer to Figure 17 for additional venting

requirements.

Figure 22

Below Grade Installation

When it is not possible to meet the required vent terminal clearances

of 12" (305mm) above grade level, a snorkel kit is recommended. It

allows installation depth down to 7" (178 mm) below grade level.

The 7" (178 mm) is measured from the center of the horizontal

vent pipe as it penetrates through the wall.
Ensure the sidewall venting clearances are observed. If venting

system is installed below ground, we recommend a window well

with adequate and proper drainage to be installed around the

termination area.

TYPICAL BASEMENT INSTALLATION

Figure 20

Examples of possible venting systems using one (1) 90° elbow.

Eight (8) feet is listed as minimum vertical vent run with 20 feet

of maximum horizontal vent run. Vertical dimensions are based on

centerline to centerline of pipe. Horizontal dimensions are based

on centerline of pipe to end of termination.

FIRESTOP AT
CEILING LEVEL

SEE GRAPH FOR PERMISSIBLE “H” AND “V” DIMENSIONS

NOTE: H1 AND H2 MUST BE ADDED TOGETHER TO USE CHART

SEE GRAPH FOR PERMISSIBLE “H” AND “V” DIMENSIONS

FIRESTOP AT
CEILING LEVEL

VENTING FIREPLACE - TOP (continued)